What to do if...?
Problem Cause Remedy
Drive is not functioning. Incorrect connection. Check connection.
Drive is running in the
wrong direction.
Incorrect connection
Swap over wire and
wire on the power
supply unit.
Automatic drive com-
mands are not ex-
ecuted.
The slide switch is set to
Manual mode.
Set the slide switch to
Automatic mode.
The set sun and wind
parameters cannot be
changed/displayed.
No sensor connected or
the connecting cable is
faulty.
Check the sensor, con-
necting cable and con-
necting plug.
Sun protection does not
travel to end position.
The running time is too
short.
Adjust the running time
in the Function menu.
End position not set. Set the end position in
the settings menu SUN
END POSITION or TIME
END POSITION.
Wind alarm is displayed
even though there is no
wind.
Cable break Check the cable, re-
place if necessary.
Wind gusts Wait approx.15
minutes.
Automatic drive com-
mands are not ex-
ecuted.
The automatic sun pro-
tection function was in-
terrupted by a manual
action, such as actu-
ation of the Up/Stop/
Down button.
Move the slide switch
from position " " into
position " " and back
to position " ".