Type of safety edge DIP 1 DIP 2 DIP 3
Pneumatic safety edge 1.2 kΩ ON ON OFF
Pneumatic safety edge 8.2 kΩ ON ON ON
Electric safety edge 1.2 kΩ ON OFF OFF
Electric safety edge 8.2 kΩ ON OFF ON
Optoelectronic safety edge OSE OFF OFF OFF
Caution
When using a pneumatic safety edge, the DIP switch 2
must always be set to the ON position, as otherwise it is
not possible to properly monitor the function of the pneu-
matic safety edge. On delivery, some safety devices may
be bridged. Before initial use, always check that no non-
permissible bridging exists.
If the safety edge is activated during travel in the DOWN direction, the door is stopped
instantly by the control unit. After an internal time of 0.3s has elapsed, the door control
unit opens the door again.
Safety edge OSE Electric safety edge Pneumatic safety edge
OSE
green = SE 1
white = 0 V
brown = 12 V