Description
Light barrier LS activated
Light barrier LS negative testing
Error running time exceeded, rota-
tional error, blockage
Stop, OPEN activated in limit position
Control unit defective, internal error
Emergency stop, slack rope activ-
ated, drive command error
Confirm by pressing and holding the
Stop button
1x
Rotary encoder error
2x
Rotary encoder communication error
3x
Limit position overrun
4x
No limit positions programmed
Lower limit position
Lower limit position, inching mode
Upper limit position
Upper limit position, inching mode
Pre-limit switch safety input (VES)
Light barrier muting
Caution
In the event of an internal error (no redundancy), the sys-
tem switches to dead-man mode for safety-related reas-
ons.
Closing is only possible using the CLOSE button on the
control unit.
19