18 | VT 4.10, VT 4.16, VT 4.25, VT 4.40, VX 4.10, VX 4.16, VX 4.25, VX 4.40
This pump variant has neither a suction filter nor a vacuum safety valve
ex works.
These must be installed by the customer before commissioning.
A direct suction connection without these safety components will
damage the pump.
Dimensioning the suction line
Make the pipes at least as large as the nominal diameter of the
connection.
For cable lengths > 2 m, the next larger cross-section must be
selected.
For pipe lengths > 5 m we recommend the additional installation of
non-return valves.
Keep connections free of oil, grease, water and other contamination.
The supply line is to be installed by means of a flexible hose or fixed pipe
in such a way that no mechanical tension is applied to it.
Size
Connection
VT 4.10
G 1/2 "
VT 4.16
G 1/2 "
VT 4.25
G 3/4 "
VT 4.40
G 3/4 "
VT 4.40/0-90
G 1 "
VX 4.10
G 1/2 "
VX 4.16
G 1/2 "
VX 4.25
G 3/4 "
VX 4.25/0-47
G 3/4 "
VX 4.40
G 3/4 "
Table 6.2: Connection sizes (suction side)
6.2.2 ADJUST VALVE
Adjusting the vacuum
The pump is equipped with a vacuum regulating valve, which allows the
vacuum required for the application to be set.
Depending on the size, this value is limited.
Exceptions VX 4.25/0-47, where a suitable valve must be fitted before
commissioning.
6.3 ELECTRICAL INSTALLATION

Table of Contents

Other manuals for Becker VX 4.25

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Becker VX 4.25 and is the answer not in the manual?

Becker VX 4.25 Specifications

General IconGeneral
BrandBecker
ModelVX 4.25
CategoryWater Pump
LanguageEnglish

Related product manuals