32 | VT 4.10, VT 4.16, VT 4.25, VT 4.40, VX 4.10, VX 4.16, VX 4.25, VX 4.40
Variant
VT 4.40/0-90
VX 4.10
VX 4.16
VX 4.25
Volume flow min.
47 m³/h (50 Hz)
10 m³/h (50 Hz)
16 m³/h (50 Hz)
25 m³/h (50 Hz)
Volume flow max.
55 m³/h (60 Hz)
12 m³/h (60 Hz)
19 m³/h (60 Hz)
30 m³/h (60 Hz)
Vacuum
150 mbar (abs)
100 mbar (abs)
100 mbar (abs)
100 mbar (abs)
Weight
38 - 41 kg
16 kg
22,5 kg
26 - 29 kg
Sound level min.
67 dB(A) (50 Hz)
60 dB(A) (50 Hz)
61 dB(A) (50 Hz)
62 dB(A) (50 Hz)
Sound level max.
72 dB(A) (60 Hz)
62 dB(A) (60 Hz)
64 dB(A) (60 Hz)
67 dB(A) (60 Hz)
Permissible ambient
temperature
5 - 45 °C
5 - 45 °C
5 - 45 °C
5 - 45 °C
Exhaust air temperature max.
85 °C
87 °C
93 °C
118 °C
Maximum installation height
800 m ü.NN.
800 m ü.NN.
800 m ü.NN.
800 m ü.NN.
Maximum humidity of the
intake air
90 %
90 %
90 %
90 %
Table 9.2: Operating parameters
Variant
VX 4.25/0-47
VX 4.40
Volume flow min.
25 m³/h (50 Hz)
40 m³/h (50 Hz)
Volume flow max.
30 m³/h (60 Hz)
48 m³/h (60 Hz)
Vacuum
100 mbar (abs)
100 mbar (abs)
Weight
34,5 kg
38 - 41 kg
Sound level min.
55 dB(A) (50 Hz)
67 dB(A) (50 Hz)
Sound level max.
60 dB(A) (60 Hz)
72 dB(A) (60 Hz)
Permissible ambient
temperature
5 - 45 °C
5 - 45 °C
Exhaust air temperature max.
118 °C
126 °C
Maximum installation height
800 m ü.NN.
800 m ü.NN.
Maximum humidity of the
intake air
90 %
90 %
Table 9.2: Operating parameters
9.3 TECHNICAL DATA
Technical data sheets for the pumps can be found on our homepage under the following link:
www.becker-international.com/download

Table of Contents