Beckman Coulter Avanti JXN-26 User Manual

Beckman Coulter Avanti JXN-26
210 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
PN B38322AA
February 2014
User Guide
Avanti JXN Series
High Performance Centrifuges
For In Vitro Diagnostic Use
Beckman Coulter, Inc.
250 S. Kraemer Blvd.
Brea, CA 92821 U.S.A.

Table of Contents

Other manuals for Beckman Coulter Avanti JXN-26

Questions and Answers:

Beckman Coulter Avanti JXN-26 Specifications

General IconGeneral
TypeHigh-Performance Centrifuge
Max Speed26, 000 rpm
Refrigeration SystemNon-CFC, non-ozone depleting refrigerant
Acceleration/Deceleration Profiles10 deceleration rates
TimerUp to 99 hr, 59 min, Hold
Rotor CompatibilityCompatible with a wide range of rotors for various applications
User InterfaceTouchscreen

Summary

Description

Specifications

Details key operational parameters like speed, time, temperature, and dimensions.

Available Rotors

Lists various rotor types compatible with the centrifuge, including capacity and part numbers.

The Touch Screen Interface

Areas on the Screen

Describes the main UI components: Header Bar, Footer Bar, and Page Display Area.

Help Messages

Explains how to access and use the instrument's built-in online help system.

Operations

Manual Operation

Step-by-step guide for operating the centrifuge using standard manual settings.

Zonal and Continuous Flow Operation

Details advanced operational modes for specific rotors and procedures.

Configuration

Managing Your Network

Configures network settings for connectivity, email, and remote access.

Managing Users

Sets up user accounts, levels, and permissions for system access control.

Programs

Creating Programs

Guides users through the process of defining and saving custom run sequences.

Running Programs

Explains how to select and execute pre-defined or custom programs.

Functional Pages

Home Page

The primary operational screen displaying key run status and controls.

Set Speed Page

Interface for adjusting the centrifuge rotor speed or setting RCF units.

Maintenance and Troubleshooting

Maintenance

Covers routine procedures to ensure optimal performance and longevity of the instrument.

Replacing the Air Filter

Instructions for checking and replacing the instrument's air filter.

Preinstallation Requirements

Electrical Requirements

Specifies necessary power supply, wiring, and circuit breaker details for installation.

Space and Location Requirements

Details required clearances and environmental considerations for instrument placement.

Temperature Calibration Procedure

Calibrating Temperature

Procedure to measure and adjust the centrifuge's temperature control for accuracy.

Diagnostics

Diagnostics/User Messages Chart

Lists error codes, their meanings, and recommended corrective actions.

Third Party Contributions and Legal Notices

Contributions and Legal Notices

Details third-party software licenses and legal disclaimers.

HEPA Filter Replacement Instructions for the Avanti JXN Series Centrifuges

HEPA Filter Replacement

Instructions for locating and replacing the external HEPA filter assembly.