ILLUMINATION OF ALTERNATOR-OUT LIGHT
In
the
event
of
the
illumination
of
a
single
AL
TERNA
TOR-OUT UNDER
VOL
TAGE light
or
a single
AL
TERNA
TOR-OUT OVERVOLTAGE
Hght:
Check the respective loadmeter for load indication:
a.
No Load - Turn off affected alternator.
b.
Reduce load to single alternator capability.
c.
Reset the affected alternator with the alternator
switch.
Monitor
overvoltage and undervoltage
lights and loadmeter for proper operation.
CAUTION
If
proper
operation
is
not
restored, turn
alternator switch OFF.
In
the event
of
the Hlumination
of
both
AL
TERNA
TOR-OUT
UNDER
VOL
TAGE
lights
or
both
ALTERNA
TOR-OUT
o
VER
VOL
TAGE lights:
Check
loadmeters
for load indication. If condition
indicates malfunction
of
both alternator circuits:
a.
80th ALT Switches - OFF
b.
Minimize electrical load since only battery power
will be available.
c.
Reset the alternators with the alternator switches.
Monitor overvoltage and undervoltage lights and
loadmeters for proper operation.
CAUTION
If
proper
operation
is
not
restored,
turn
alternator switches OFF.
April
1979