6.0 Storing, Printing
and Data Transfer
After a successful measurement, it is possible to
save the measurement value by means of „Store”
key (27). Approximately 500 measurement values
can be saved. Proceed as follows:
After the saving process, it is possible to view the
last saved measurement result and to print a report
containing the measurement results using the pro-
tocol printer (option Cat. No. 1196).
If desired, the data may be transferred via a serial
interface to a PC for the reporting using the software
es control 0100 (option Cat. No. 1251).
6.1 Storing Measurement Data
To save the measurement data, please proceed as
follows:
Perform a measurement.
Store the measurement result by pressing the
“Store” (27) key.
After successful saving, a brief signal is audi-
ble and the symbol "M” (17) is displayed, fol-
lowed by the brief display of the continuous
memory location number.
If the memory is full and the key “Store” (27) is
pressed, the symbol "M" (17) is briefly displayed and
an error signal is audible.
The saved data is kept in the memory even
when the appliance is switched off.
It is not possible to save a measurement value
twice!
Under certain unfavourable conditions, data
may be lost or modified with any electronic
memory. The company CH. BEHA GmbH will
not be held responsible, neither for financial
nor for any other losses caused by data loss,
incorrect handling, or any other reason.
We highly recommend to perform a daily
measurement data transfer to a PC and to
save the data. The measurement data with-
in the measurement appliance might be lost
by unforeseeable and exterior influences
(drop, electro-magnetic influence, etc.).
6.2 Viewing Measurement Data
Respectively, the last measurement value can be
displayed.
To view measurement data, please proceed as fol-
lows:
Briefly press the key “Clear/Recall” (29). The
last memory location number is displayed.
After this, the measurement data and the pre-
selected limit values are displayed for approx.
2 seconds.
Attention, extended pressing (longer than 2s)
of the key “Clear/Recall” (29) causes the last
measurement value to be deleted.
30
Storing, Printing and Data Transfer

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BEHA Unitest TELARIS 0100 plus and is the answer not in the manual?

BEHA Unitest TELARIS 0100 plus Specifications

General IconGeneral
BrandBEHA
ModelUnitest TELARIS 0100 plus
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals