– 35 –
© behr Labor-Technik 2013
249101
Heating Cannot be Switched Off
Heating
Off
Error No. 011
Error
The heating was operating continuously. Presumably,
the triac is defective.
Turn the apparatus immediately off and contact the
behr customer service!
Excessive pressure in the steam generator
Steam generator
Pressure
Error No. 020
Error
There is excessive pressure in the steam generator.
Turn the apparatus off immediately and contact the
behr customer service!
Level sensor error
Steam generator
Sensor
Error No. 021
Error
The fill level sensor of the steam generator is giving a
false signal.
Turn the apparatus off immediately and contact the
behr customer service!
Lack of water in the steam generator
Steam generator
H2O On
Error No. 022
Error
The water feed pump could not fill the steam genera-
tor within 30 seconds. This error may occur in several
situations:
After completely refilling the steam generator.
If you had to empty and refill the steam generator: when
the message appears, just switch the device off and
on again. Repeat this one or two more times; then the
steam generator is full and the device can be operated
again.
If the feed-water container is empty or the feed hose
is kinked or clogged or incorrectly connected.
Switch the device off. Refill the feed-water container and
check the hose connections; then switch the device on
again.
If the error cannot be remedied this way,
the pump or
the valves or tubings within the device will be defective.
Turn the apparatus off immediately and contact the
behr customer service!