7 General specification
BFI-H3
Over
C
urrent
1
25
%
of rated current for 2,0
s; 1
10 %
for
1 min
Output
V
oltage
3
-
fas, 0 V
to Supply voltage
Output
F
requency
0
–
50
0
Hz
Input Voltage
1
-
phase
, 200
–
240 VAC
3
-
phase
, 380
-
480 VAC
Voltage Fluctuation
s
180
–
26
4 VAC
342
–
528 VAC
Phase Imbalance
Maximum 3 % between phases for f
ull load operation
Input
F
requency
48
-
62 Hz
Internal Braketransitor
No
Switching
F
requency
4, 8, 12, 16, 24 or 32 kHz
. Increased switching frequency might decrease output cur
rent.
Control Methods
Constant torque, Variable torque, Voltage boost, PM motor support, , Brushless DC motor (BLDC) support,
Synchronus reluctance motor support
Start
M
ethods
Digital,
Hand/Auto buttons
, Keypad,
Modbus RTU
, Bacnet and Fieldbuses
Frequency Setpoint
Digital Preset speed, Digital motor potentiometer, analogt 4 – 20 mA, 0 –10 V, Scaling of digital setpoint
Keypad,
Modbus RTU
, Bacnet
,
Fieldbuses
and Ethernet.
Digital Input
3 x Programmable Digital Input and 2 x User-selectable Digital or Analog Inputs,
Analog Input
2 x User-selectable Digital or Analog Inputs. 4-20 mA or 0-10 V , 12 bits
Relay Output
2 x Progammable Relay (single pole and 2-pole ), Maximum load 6,0 A with 230 V or 5A with 30 VDC.
Digital Output Signals
Drive enabled, Drive healthy, At Target Frequency, Output Frequency ≥ Limit, Output Current ≥ Limit, Analog
Input 2
Level
≥
Limit, Fire Mode Active, Maintenance, Drive Available, Assist Pump 1 Control
Analog Output
2 x User-selectable Digital or Analog Output, 0-10 V DC. Maximum current 20 mA. 10 bit.
Analog Output Signals
Output Frequency, Output motor current or Output motor power.
Safety Inputs
One with sink logic and one with source output
Communication
Modbus RTU and BacNet onboard.
Profibus DP, CC
-
Llink, Device Net, Ethernet IP, Mod
bus TCP, Profinet, Ethercat by
optionboard
Acc/Deceration
T
ime
0 to 60
0
0 sec,
2:nd decel
e
rat
i
on ramp
,
Stop
M
ode
Ramping / Fast stop / Coasting / DC
-
brake
Zero speed holding time
Motor
O
verload
protect.
C
urrent
limit,
Input and output loss phase detec
tion
,
Trip level is resistance
>
2,5 kOhm
General Functions
PID-control, Built-in plc, Spin start, Standby mode, Automatic restart, Skip frequency, Stop method at Voltage
interruption,
Ener
g
y Optimi
zer
,
Parameter access lock,
HVAC
F
unctions
Fire Mode, S
tir, Pipe fill protection, Mot
or preheating, Cascade mulit
pump, Pump cleaning function
Protection
C
lass
EN60529 : 1992
,
IP20,
IP55
or IP66
Ambient
T
emperature
IP20:
-
10 ºC to +50 ºC
,
IP
55/
66:
-
10 ºC to +
4
0 ºC, Storage temperature
is
-
40 ºC to +60 ºC
Maximum
H
umidity
Max. 95 % n
on
-
condensing
Environment
No airborne dust, corrosive gases or liquids, conductive contaminants (such as condensation, carbon dust, and
metallic particles), high moisture, salt or chemical content environments
Maximum
A
ltit
ude
2000 meter bove sea level,
Derate avove 1000 m: 1 %/10
0m
Vibration
s
IEC 60068
-
2
-
29, IEC 60068
-
2
-
64, IEC 60068
-
2
-
6
Safety
F
unctions
IEC 61608, IEC 61800
-
5
-
2, IEC 62061, ISO 13849
EMC
Use shielded motor cable. Built-in EMC-filter,
- EN61800-3:2004, 1*230 VAC: Class C1, C2, C3 och C4
-
EN61800
-
3:2004, 3*40
0 VAC: Class C2, C3 och C4
Harmonics
EN61000-5-12, Limits for harmonic currents produced by equipment connected to public low-voltage systems
with input current > 16 A and < 75 A per phase. Requirements are fulfilled without the need for Line Reactors
acc
ording to the THC values specified in Table 3 for values of R
SCE
> 185
Approvals
CE, cUL, UL, RoHS, Carbon Trust
Max
M
otorcab
le
L
e
n
gth
100
meter
BFI-H3 (1x 230 V)
BFI-H3 (3 x 400 V)
BFI Modell
043 070 105
022 041 058 095 140 180 240 300 390
Output
Power, kW
0,75
1,5
2,2
0,75
1,5
2,2
4,0
5,5
7,5
11
15
18,5
Rated Output Current A,
4,3 7,0 10,5
2,2 4,1 5,8 9,5 14,0 18,0 24,0 30 39
Frame Size
2
2
2
2
2
2
2
3
3
3
4
4
Weight
1,8
1,8
3,5
12
IP
-
class
20/66
20/66
55
BFI-H3 (3 x 380-480 V)
Drive Model
460 610 720 900 1100 1500 1800 2020 2400 3020 3700 4500
Output Power, kW
22
30
37
45
55
75
90
110
132
160
200
250
Rated Output Current A,
46 61 72 90 110 150 180 202 240 302 370 450
Frame Si
ze
4
5
6
7
8
Weight
12
23
55
89
128
IP
-
class
20/
55
55
20