EasyManua.ls Logo

BEKA BEKA-MAX - 7.6.7 Dual Line System Error Reports

Default Icon
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© BEKA 201 All rights reserved5!
...a product of BEKA
Line related errors / warnings:
· Error solenoid valve 1 or 3 is missing
· No pressure build up in line 1 or 2
· Pressure drop in line 1 or 2
· Warning cycle monitoring
If more error or warnings are shown, a small arrow is displayed. Use also the control buttons to scroll up and down as well
as to the right and left.
Fig. 23:
The control unit does not differ if the error is line or global related, neither in which line the error has
occured. The sorting is done merely acc. to error and warnings. First the errors are shown, then the
warnings.
7.6.7 Read out error and warnings when using a dual line lubrication system
The error and warning report can be read out via the display of the control unit or by means of the software BEKA-DiSys
(from version V4.0.8.502).
· Press OK to get into setting mode.
· Use the control buttons to get to menu „error messages“ and confirm with OK.
Fig. 24:
ERROR
no pressurization
line1
settings
error messages
*
Note!
23