With Auto-Mute off, unit will provide a continuous
series of X, K, Super Wideband Ka or Laser audio
alerts. This standard setting is often preferred when
background noise in a vehicle is loud. Factory setting
is Auto-Mute off. Auto-Mute
ON is confirmed by the
FULL illumination of all 4 red
LEDs in the signal
strength meter. Auto-Mute off is confirmed when the
same 4 red
LEDs flash.
Safety Warning System
®
(SWS
) – LED#1
When activated, unit will detect signals from SWS
transmitters and provide audio/visual warnings if
SWS
transmitters are in use. Factory setting is ON.
X Band On/Off – X BAND LED
When activated, unit will detect X Band signals
(10.456
GHz - 10.60 GHz).
K Band On/Off – K BAND LED
When activated, unit will detect K Band signals
(24.050
GHz - 24.205 GHz).
Super Wideband Ka On/Off – KA BAND LED
When activated, unit will detect Super Wideband Ka
signals (33.4
GHz - 36.0 GHz).
Ka Narrow Band (33.8 GHz) On/Off (LED#1)
When activated, unit will detect ONLY the 33.8 GHz
segment of the Ka bandwidth.
Ka Narrow Band (34.36 GHz) On/Off (LED#2)
When activated, unit will detect ONLY the 34.36 GHz
segment of the Ka bandwidth.