20
TM
1. Turn on water supply to full.
2. Purge the air from the pump by releasing the safety and squeezing the
trigger of the spray gun until a steady stream ows out.
3. Turn the fuel valve to OPEN position.
4. Turn the choke lever to START position.
5. Turn the throttle lever to full throttle (Rabbit).
6. Turn the engine power switch to the ON position.
7. Pull the recoil starter slowly until resistance is felt, then pull rapidly.
Squeeze the gun trigger and release the water pressure after every failed
attempt to start the pressure washer.
8. Let engine run for several seconds and then slowly turn the choke lever
towards RUN as the engine warms up until the choke is fully in RUN
position.
NOTE
DO NOT allow the unit to run for more than 2 minutes without pulling
the trigger to release water pressure. This could cause overheating and
damage to the pump. When the temperature inside the pump gets too
high the thermal relief valve will temporarily open and release a spray of
water from the pump to lower the internal temperature.