9. TROUBLESHOOTING
Problem Possible Cause Solution
Engine will
not start
No gasoline
Engine oil low
Choke is in the
incorrect position
Water pressure built up
after two recoil pulls
Spark plug cap
disconnected
Fouled spark plug
Add fuel
Add engine oil
Move choke to the Start
position
Squeeze the trigger after
each failed recoil start to
release the pressure
Connect spark plug cap
Replace spark plug
Engine hard
to start
Stale fuel or water in
fuel
Drain fuel and rell with
fresh gas
Engine lacks
power and
vibrates
excessively
Choke in the Start
position
Dirty air lter
Move choke to the Run
position
Clean air lter
Engine loses
power when
load is added
Engine speed too low Move throttle to full
power (rabbit icon)
Not reaching
high pressure
Low pressure black
detergent nozzle is
attached
Low water supply
Water supply is
restricted
Water inlet lter is
clogged
Nozzle obstructed
High pressure hose is
too long
Remove and attach a
high pressure nozzle
Water supply must be
from a 3/4" diameter
hose minimum
Check hose for leaks,
kinks, or blockages.
Ensure the water supply
tap is all the way open.
Remove lter and rinse in
warm water. Reinstall.
See nozzle cleaning
instructions
Max high pressure hose
of 100 feet (30m)

Table of Contents

Other manuals for Benchmark BW Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Benchmark BW Series and is the answer not in the manual?

Benchmark BW Series Specifications

General IconGeneral
BrandBenchmark
ModelBW Series
CategoryPressure Washer
LanguageEnglish

Related product manuals