76 Bend-Tech Dragon A150
Troubleshooting Guide
Mach3
16
Symptom Cause Corrective Action
Cannot bring Mach 3 out
of emergency mode:
E-stop is activated Ensure E-stops are active
Machine not plugged in/not
getting power
Ensure machine is plugged in and has
power
Axis resting on a homing
switch
Ensure no homing switches are
triggered
Breakout Board has lost
connection with ESS board

seated on ESS board
Check 25-pin parallel cable
for connectivity
Replace 25-pin parallel cable