LR-10000 Low-Rise Scissor Lift 24 P/N 5900075 — Rev. B — August 2021
Preparing the Power Unit
The Power Unit comes fully assembled from the factory. You need to attach it to the Power Unit Stand
(already done, as described in Anchor the Power Unit Stand and Attach the Power Unit),
connect it to a power source, and fill the Hydraulic Fluid Reservoir with Hydraulic Fluid.
The Power Unit for the LR-10000 is 208–240 VAC, 50/60 Hz, 1 phase. The Hydraulic Fluid Reservoir
holds about 5.65 liters (1.5 gallons) of Hydraulic Fluid.
The Lift uses electrical energy; if your organization has Lockout/Tagout policies, make sure to
implement them once the unit is connected to a power source.
⚠ DANGER All wiring
must
be performed by a licensed, certified Electrician.
Refer to Wiring Diagrams for wiring information.
⚠ CAUTION The Power Unit’s motor is
not
thermally protected.
The Power Unit has multiple connections:
• Hydraulic Hose. The Hydraulic Hose should already be connected to the Power Unit. If it is not,
refer to Connect the Hydraulic Hoses for more information.
• Power Source. The Power Unit has to connect to an appropriate power source.
The following drawing shows the Power Unit of the LR-10000.
Your Power Unit may be different from what is shown here. Drawing is not necessarily to scale.