XPR-10 Series Two-Post Lifts 22 P/N 5900951 ā Rev. D ā May 2019
The following procedure puts the two Equalizing Cables into place at the bottom of the Post; it is not a
full install of the Equalizing Cables.
To put the Equalizing Cables into position:
1. Put both Posts either flat on the ground or mostly on the ground with their tops elevated on a
sawhorse or similar.
The
insides
of the Posts need to be accessible, facing up.
2. Slide the Lift Heads away from the bottoms of both Posts by at least 24 inches / 610 mm, to give
yourself some space to work.
Not necessarily to scale. Not all components shown. Top view looking at inside of Post. Equalizing
Cables not yet in place.