LIFT WILL NOT RAISE
possible cause
1. Air in oil, (1,2,7,12)
2. Cylinder binding, (8)
3. Cylinder leaks internally, (8)
4. Motor run backward under pressure, (10)
5. Lowering valve leaks, (3,4,9,10)
6. Motor runs backwards, (6,13,10)
7. Pump damaged, (9,10)
8. Pump won’t prime, (1,3,7,9,10,11,12,13)
9. Relief valve leaks, (9,10)
10. Voltage to motor incorrect, (6,10,13)
11. Valves not closed fully or correctly (14)
remedy insTrucTion
1. Check for proper oil level. . . . . . . . . . . . . . . . . . . . . . . . . . The oil level should be up to the bleed screw
in the reservoir with the lift all the way down.
2. Bleed cylinders. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See Installation Manual
3. Flush release valve to get rid of. . . . . . . . . . . . . . . . . . . . . Simultaneously hold the lower button and the raise
possible contamination button allowing unit to run for 15 seconds.
4. Dirty oil. . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . Replace oil with clean AW32 hydraulic oil.
5. Tighten all fasteners. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tighten fasteners to recommended torques.
6. Check if motor is wired correctly. . . . . . . . . . . . . . . . . . . . . . .Compare wiring of motor to electrical diagram on
drawing.
7. Oil seal damaged or cocked . . . . . . . . . . . . . . . . . . . . . . . . Replace oil seal around pump shaft.
8. See Installation Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . Contact BendPak Customer Support.
9. Replace with new part . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Replace with new part.
10. Return unit for repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Return unit for repair.
11. Check pump-mounting bolts . . . . . . . . . . . . . . . . . . . . . . . . Bolts should be 15 to 18 ft. lbs.
12. Inlet screen clogged . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Clean inlet screen or replace.
13. Check wall outlet voltages and wiring . . . . . . . . . . . . . . . . . Make sure unit and wall outlet are wired properly.
14. Check all valves inside console . . . . . . . . . . . . . . . . . . . . .Make sure ALL valves are fully in the CLOSED position
except for the MAIN valve.