The manual mode allows the user to individually operate the control outputs (digital outputs and analog
outputs) manually. This feature is very helpful for kiln commissioning. Caution: For safety reasons only enable
this MODE if the operator is familiar with it !
This feature allows automatic commencing programmes by the weekly switching clock. Depending on
configuration up to 99 real time clock / weekdays controlled jobs can be entered. Enable this feature only if
necessary to avoid unintentional programme commencing
Allows locking of all programmes (temperature curves) to avoid any unauthorized changes
Sets the communication ID of the controller. Affects external communication only. Make sure that this ID fits
the setting in the communcation software (e.g. bentrup WinControl). Each ID must be unique on the
communication network
(value range 9600 to 38400)
Baud rate of the communication
Verhalten nach dem Einschalten: 0=Regler aus (IDLE), 1/2=automatischer Programmstart wenn alle
Bedingungen erfüllt sind (1=Zeit-Limit in Sekunden / 2=Zeit-Limit in Minuten). 3=automatischer Programmstart
Programme is continued only if the selected output was ON before power breakdown. When selecting and
output controlled by a programme EVENT, this feature can be used to enable programme continuation after a
power breakdown for each segment
Programme is continued only if the duration of the power failure was less than this parameter. Depending on
the selection of "fctn. on pow. up" this time limit is seconds or minutes
(value range OFF, IN00 to IN03)
Selects the process value check for drop in temperature during a power breakdown
(value range -9999 to 9999)
Programme is continued only if the selected process value did not drop more than a the given value during
power breakdown