7
The manual mode allows the user to individually operate the control outputs (digital outputs and analog
outputs) manually. This feature is very helpful for kiln commissioning. Caution: For safety reasons only enable
this MODE if the operator is familiar with it !
04: auto P. starts
This feature allows automatic commencing programmes by the weekly switching clock. Depending on
configuration up to 99 real time clock / weekdays controlled jobs can be entered. Enable this feature only if
necessary to avoid unintentional programme commencing
05: lock programs
Allows locking of all programmes (temperature curves) to avoid any unauthorized changes
06: communicat. ID
Sets the communication ID of the controller. Affects external communication only. Make sure that this ID fits
the setting in the communcation software (e.g. bentrup WinControl). Each ID must be unique on the
communication network
07: RS485 baudrate
Baud rate of the communication
08: fctn.on pow.up
Verhalten nach dem Einschalten: 0=Regler aus (IDLE), 1/2=automatischer Programmstart wenn alle
Bedingungen erfüllt sind (1=Zeit-Limit in Sekunden / 2=Zeit-Limit in Minuten). 3=automatischer Programmstart
09: ..only if Dxx
Programme is continued only if the selected output was ON before power breakdown. When selecting and
output controlled by a programme EVENT, this feature can be used to enable programme continuation after a
power breakdown for each segment
10: only if t<time
Programme is continued only if the duration of the power failure was less than this parameter. Depending on
the selection of "fctn. on pow. up" this time limit is seconds or minutes
11: dT input sel
Selects the process value check for drop in temperature during a power breakdown
12: ..only if dT<x
Programme is continued only if the selected process value did not drop more than a the given value during
power breakdown
.