LaserSpeed 8000/9000 I/O Module Instruction Handbook
Setup
Part No. 93342 / Drawing No. 0921-01516 Page 49 of 84 Revision E (Dec 2013)
~I:ReadyLn Parallel Port Data Ready Pulse Length
~I:ReadyLn<CR> Read Setting
Response Format:
ParallelPort ReadyLn <N><CR>
~I:ReadyLn=<N><CR> Set Value
Factory Default: 8 Minimum: 1 Maximum: 255
Where <N> indicates the length of the Data Ready Output Pulse. This is an
integer value from 1 to 255. This allows a pulse length from 500µs to
approximately 125ms in 500µs increments. The value for this setting can be
calculated with the following formula:



Example: To set the Data Ready strobe width to 10ms:






To configure the value, send the command ~I:ReadyLn=20<CR>
~I:Elongation Parallel Port Elongation Mode
~I:Elongation<CR> Read Setting
Response Format:
ParallelPort Elongation <N><CR>
~I:Elongation=<N><CR> Set Value
Factory Default: 1 Minimum: 0 Maximum: 1
Where <N> indicates the on/off status of Auto-Elongation Mode.
Value
Auto-Elongation Mode
0
Disabled
1
Enabled