LaserSpeed 8000/9000 I/O Module Instruction Handbook
Setup
Part No. 93342 / Drawing No. 0921-01516 Page 51 of 84 Revision E (Dec 2013)
~I:LenRes Parallel Port Length Resolution
~I:LenRes<CR> Read Setting
Response Format:
ParallelPort ElongRes <N><CR>
~I:LenRes=<N><CR> Set Value
Factory Default: 1 Minimum: 0.001 Maximum: 1
Where <N> indicates the Length resolution multiplier.
Value
Length Multiplier
1
Length x 1
0.1
Length x 0.1
0.01
Length x 0.01
0.001
Length x 0.001
This command allows to user to reduce the output resolution of the length
measurement by scaling the measurement result.
Example: To reduce the length resolution by a factor of 10x
~I:LenRes=0.1<CR>.