When n≠0, the printer feeds the paper to (cutting position+[n×0.125
mm (0.0049”)]) and cuts it.
ESC P m t1 t2 (for Drawer)
Generate pulse
ASCII:
27 112 m
1B 70 m
t1
t1
t2
t2
Hexadecimal:
m=0,1,48,49
0≤t1≤255, 0≤t2≤255
Outputs the pulse specified by t1 to connector pin m as follows:
0,48
1,49
Drawer kick-out connector pin2.
Drawer kick-out connector pin5.
λ
The pulse ON time is [t1×2ms] and the OFF time is [t2×2ms].
If t2<t1, the OFF time is [t1×2ms].
Enable/disable panel buttons
99 53 n
03 35 n
Hexadecimal:
0≤n≤255
Enable/disable panel buttons
(
support the panel buttons
)
When the LSB of n is 0, the panel buttons are enabled.
When the LSB of n is 1, the panel buttons are disabled.
GS ( F pL pH a m nL nH (for 701BM)
29 40 70 pL pH a m nL nH
1D 28 46 pL pH a m nL nH
(pL+(pH×256))=4 (where pL=4, pH=0)
1≤a≤2
0≤( nL+nH×256) ≤65535 (where 0≤nL≤255, 0≤nH≤255)
This command is effective only when the BM sensor is enabled.
Sets adjustment values(s) for the printer operations specified by a.
pL and pH specifies the number of the parameter such as a to