λ
When n≠0, the printer feeds the paper to (cutting position+[n×0.125
mm (0.0049”)]) and cuts it.
ESC P m t1 t2 (for Drawer)
[Name]
Generate pulse
ASCII:
[Format]
ESC p m t1
t2
Decimal:
27 112 m
1B 70 m
t1
t1
t2
t2
Hexadecimal:
m=0,1,48,49
0≤t1≤255, 0≤t2≤255
[Range]
[
Description]
Outputs the pulse specified by t1 to connector pin m as follows:
m
Function
0,48
1,49
Drawer kick-out connector pin2.
Drawer kick-out connector pin5.
[Note]
λ
λ
The pulse ON time is [t1×2ms] and the OFF time is [t2×2ms].
If t2<t1, the OFF time is [t1×2ms].
ESC c 5 n(for buttons)
[Name]
Enable/disable panel buttons
[Format]
ASCII:
ESC c
5 n
Decimal:
27
99 53 n
03 35 n
Hexadecimal:
0≤n≤255
1B
[Range]
[Description]
Enable/disable panel buttons
(
support the panel buttons
)
λ
When the LSB of n is 0, the panel buttons are enabled.
When the LSB of n is 1, the panel buttons are disabled.
λ
[Default]
n=0
GS ( F pL pH a m nL nH (for 701BM)
[Name]
[Format]
ASCII:
GS (
F pL pH a m nL nH
Decimal:
29 40 70 pL pH a m nL nH
1D 28 46 pL pH a m nL nH
Hexadecimal:
[Range]
(pL+(pH×256))=4 (where pL=4, pH=0)
1≤a≤2
m = 0, 48 or 1, 49
0≤( nL+nH×256) ≤65535 (where 0≤nL≤255, 0≤nH≤255)
This command is effective only when the BM sensor is enabled.
Sets adjustment values(s) for the printer operations specified by a.
[Description]
λ
pL and pH specifies the number of the parameter such as a to