23 System Configuration Commands
Examples
Configure MU chairperson functionality (muad = 0x79B7)
Transmit:
Receive:
M 79B7<CR>
<CR><LF>
MUAD=0x000079B7<CR><LF>
>
This command switches to unicast mode, which affects
the MU with MU ID 0x79B7.
Transmit:
Receive:
~J 4 2<CR>
<CR><LF>
>
This command sets the MU to chairman functionality.
Transmit:
Receive:
M 0<CR>
<CR><LF>
MUAD=0x00000000<CR><LF>
>
This command switches back to broadcast mode.
Configure MU for MU Zone 2 (muad = 0x79B7)
Transmit:
Receive:
M 79B7<CR>
<CR><LF>
MUAD=0x000079B7<CR><LF>
>
This command switches to unicast mode, which affects
the MU with MU ID 0x79B7.
Transmit:
Receive:
~J 5 01<CR>
<CR><LF>
>
This command sets the MU to MU Zone 2.
Transmit:
Receive:
M 0<CR>
<CR><LF>
MUAD=0x00000000<CR><LF>
>
This command switches back to broadcast mode.