EasyManua.ls Logo

Binder BD 240 - User Manual

Default Icon
69 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Issue 03/2019 Art. No. 7001-0026
Operating Manual
Translation of the original operating manual
BD / BD-UL (E2) Incubators with natural convection
ED / ED-UL (E2) Drying and heating ovens with natural convection
FD / FD-UL (E2) Drying and heating ovens with forced convection
with microprocessor temperature controller
Modell Model version Art. No. Modell Model version Art. No.
BD 23
BD023-230V 9010-0187
ED 240
ED240-230V 9010-0101
BD023UL-120V 9010-0189 ED240UL-208V 9010-0167
BD 53
BD053-230V 9010-0081
ED400
ED400-230V 9010-0075
BD053UL-120V 9010-0179 ED400UL-208V 9010-0168
BD 115
BD115-230V 9010-0088
ED720
ED720-230V 9010-0076
BD115UL-120V 9010-0181 ED720UL-208V 9010-0169
BD 240
BD240-230V 9010-0095
FD 23
FD023-230V 9010-0194
BD240UL-120V 9010-0183 FD023UL-120V 9010-0196
BD400
BD400-230V 9010-0073
FD 53
FD053-230V 9010-0082
BD400UL-120V 9010-0176 FD053UL-120V 9010-0128
BD720
BD720-230V 9010-0074
FD 115
FD115-230V 9010-0102
BD720UL-120V 9010-0177 FD115UL-120V 9010-0129
ED 23
ED023-230V 9010-0190/0191
FD 240
FD240-230V 9010-0104
ED023UL-120V 9010-0192/0193 FD240UL-208V 9010-0130
ED 53
ED053-230V 9010-0078/0079
ED053UL-120V 9010-0131/0132
ED 115
ED115-230V 9010-0096/0097
ED115UL-120V 9010-0164/0165
BINDER GmbH
Address: Post office box 102, 78502 Tuttlingen, Germany Phone: +49 7462 2005 0
Fax: +49 7462 2005 100 Internet: http://www.binder-world.com
E-mail: info@binder-world.com Service Hotline: +49 7462 2005 555
Service Fax: +49 7462 2005 93 555 Service E-Mail: service@binder-world.com
Service Hotline USA: +1 866 885 9794 or +1 631 224 4340 x3
Service Hotline Asia Pacific: +852 390 705 04 or +852 390 705 03
Service Hotline Russia and CIS: +7 495 988 15 16

Table of Contents

Questions and Answers

  • T
    Thomas NelsonAug 17, 2025
    Why is my Binder BD 240 Climate chamber not working?
    • D
      davidosbornAug 17, 2025
      Your Binder Climate chamber might not be working due to several reasons. First, check the connection to the power supply. Second, the chamber fuse might have responded, so check it and replace it if needed. If it responds again, contact BINDER service. Finally, the controller could be defective, in which case you should also contact BINDER service.
  • W
    William SantiagoAug 20, 2025
    What to do if Binder Climate chamber set-point temperature is not reached?
    • P
      Paul BeckerAug 20, 2025
      If the set-point temperature isn't reached in your Binder Climate chamber, ensure the chamber door is completely closed. Also, inspect the door gasket and replace it if it’s defective. Calibrate and adjust the controller. Finally, check the power supply to ensure the voltage is correct (115V or 230V).
  • B
    burkedennisAug 22, 2025
    Why Binder BD 240 doesn’t heat up but controller display working?
    • A
      adam27Aug 23, 2025
      If your Binder Climate chamber isn’t heating up, and the red heating control light is off but the controller display is working, it could be due to the timer being run off. Program the timer or switch to continuous operation. Another cause might be a defective semiconductor relay, in which case you should contact BINDER service.
  • M
    michaelnelsonAug 26, 2025
    What to do if Binder BD 240 Climate chamber isn't working and the red alarm light is on?
    • L
      Larry GutierrezAug 26, 2025
      If your Binder Climate chamber isn't working and the red alarm pilot lamp is lit, it could be that the safety device class 2 has turned off the chamber. Let the chamber cool down and then press the RESET button. Also, the safety device class 2 might be defective, in that case contact BINDER service.
  • M
    Michael WeaverAug 28, 2025
    Why is my Binder BD 240 Climate chamber heating permanently?
    • B
      Brenda GibsonAug 28, 2025
      If your Binder Climate chamber is heating permanently and not maintaining the set-point, the controller may be defective, in that case contact BINDER service. Alternatively, the controller might need calibration and adjustment.
  • B
    Brenda SotoAug 31, 2025
    How to fix high temperature and red alarm on Binder BD 240 Climate chamber?
    • D
      Donald McdonaldAug 31, 2025
      If the temperature inside your Binder Climate chamber is too high and the red alarm light is on, the safety device class 3.1 may have been triggered. Check the settings of the temperature set-point and of the safety device class 3.1.
  • D
    Daniel FergusonSep 2, 2025
    Why does my Binder Climate chamber take longer to heat up?
    • L
      Lisa MurraySep 2, 2025
      If you're experiencing deviations from the indicated heating-up times with your Binder Climate chamber, it might be because the chamber is fully loaded. Try loading the chamber with fewer items or allow for longer heating-up times.
  • T
    Tammy PattonSep 5, 2025
    Why is my Binder BD 240 in stand-by mode?
    • R
      Rachel NelsonSep 5, 2025
      If your Binder Climate chamber is without function and only the green 'stand-by' LED is lit, the chamber is likely in stand-by mode. Press the ON/OFF button until the display lights up.
  • P
    Peter MaddoxSep 8, 2025
    What to do if Binder BD 240 fan is not working?
    • J
      jamessanchezSep 8, 2025
      If the fan in your Binder Climate chamber isn’t turning or is turning too slowly, the fan might be defective, in that case contact BINDER service.
  • J
    Julie NunezSep 12, 2025
    Why does my Binder BD 240 Climate chamber controller return to normal display?
    • D
      Denise CarlsonSep 12, 2025
      If the controller on your Binder Climate chamber returns to the Normal Display from any level, it's likely because no button was pressed for approximately 30 seconds. Repeat your entries, entering the values more rapidly.

Summary

Safety

General Installation & Operation Safety

Crucial safety guidelines for installing and operating the chambers.

Intended Use

Specifies the approved applications and limitations for chamber usage.

Accident Prevention Measures

Outlines safety measures implemented by the manufacturer to prevent incidents.

Chamber Description

Delivery, Transportation, Storage, and Installation

Safe Lifting and Transportation

Provides essential instructions for safe handling during lifting and transportation.

Installation Site and Ambient Conditions

Specifies suitable installation locations and environmental conditions for operation.

Equipment Installation

Electrical Connection

Step-by-step instructions for connecting the equipment to the power supply.

Start Up

Chamber Power-On Procedure

Guides on the initial steps for turning on and starting the chamber.

Controller Operation

Temperature Set-Point Entry (No Ramp)

Instructions for setting the temperature without utilizing ramp functions.

Temperature Set-Point Entry (With Ramp)

Procedures for setting temperature values when using programmed ramps.

Time Functions: Continuous and Timer

Explains the two primary time-based operation modes: continuous and timer.

Timer Operation: Setting Time

Steps required to set the tempering time for timer-based operation.

Entering a Temperature Ramp

How to program specific temperature ramps for heating processes.

Temperature Safety Devices

Class 2 Safety Device (ED, FD)

Details the function and settings for Class 2 safety devices on ED/FD models.

Class 3.1 Safety Device (BD)

Explains the Class 3.1 safety device for BD models, including optional ED/FD use.

Options

Maintenance, Cleaning, and Service

Maintenance and Service Intervals

Outlines recommended maintenance schedules and procedures for optimal chamber performance.

Troubleshooting

Fault Description and Solutions

A guide to common issues, their causes, and required corrective measures.

Technical Description

BD Model Technical Data

Comprehensive technical specifications for the BINDER BD series chambers.

ED Model Technical Data

Comprehensive technical specifications for the BINDER ED series chambers.

FD Model Technical Data

Comprehensive technical specifications for the BINDER FD series chambers.

Certificates and Declarations of Conformity

Binder BD 240 Specifications

General IconGeneral
BrandBinder
ModelBD 240
CategoryClimate chamber
LanguageEnglish

Related product manuals