FED (E2) 12/2014 page 27/55
4. Set the required address with buttons
.
You can enter address values between 1 and 30.
The set value is automatically adopted after 2 seconds.
6.4.4 Selecting the timer function
The unit provides three different timer functions:
Delayed off (setting 0”)
After the defined time has elapsed, the heating is turned off.
Temperature-controlled delayed off (setting 1”)
The defined time only begins to run when the current value is by 1 °C below the set point. After the
defined time has expired, the heating is turned off.
Delayed on (setting 2”)
After the time set has passed, the heating is turned on and remain in continuous operation.
1. Press down
button for approx. 5 seconds.
The display alternately shows unitand the temperature unit:
2. Press again button
.
The display alternately shows rASdand the set-point gradient:
3. Press again button
.
The display alternately shows Adrand the unit address:
4. Press again button
The display alternately shows tFCtand the actual setting of the timer function:
5. Set the desired timer function 0, 1 or 2 with buttons
.
The set value is automatically adopted after 2 seconds.