Why have programs been deleted from my Binder Laboratory Equipment?
- AAngela PhelpsSep 12, 2025
If programs have been deleted, ensure that the programs are no more needed when changing from 2 programs to 1 program or vice-versa.
Why have programs been deleted from my Binder Laboratory Equipment?
If programs have been deleted, ensure that the programs are no more needed when changing from 2 programs to 1 program or vice-versa.
Why does the Binder FP 240 Laboratory Equipment controller return to Normal Display from any level?
If the controller returns to Normal Display from any level, repeat entries and enter the values rapidly. This happens when no button was hit for more than 120 seconds.
Harmonized denominations, symbols, signal words, and pictograms for dangerous situations.
Guidance on safe installation, operation, and usage of BINDER chambers and accessories.
Details on power connection, plugs, voltage, and electrical safety requirements.
Initial settings and display indications for the RD3 controller upon chamber startup.
Selecting between 'Ramp' and 'Step' for temperature transitions and its implications.
Procedure for entering set-points for program sections via the program editor.
Selecting a program and defining parameters like delay time and number of cycles.
Settings for menu language, program types, section duration, and set-point programming.
Step-by-step instructions for entering program data into the program editor.
Explanation of displayed alarm messages and buzzer activation/reset.
Function, setting, and checking of the Class 2 temperature safety device.
Function, setting, and checking of the optional Class 3.1 temperature safety device.
Detailed instructions for cleaning the chamber interior, exterior, and components with recommended agents.
Steps for decontaminating the chamber after exposure to hazardous substances.
Procedure for disposing of the chamber in Germany according to WEEE regulations.
Procedure for disposing of the chamber in other EU states according to WEEE regulations.
Common faults related to heating performance and their possible causes and solutions.
Troubleshooting common faults related to the program controller's operation and settings.
Detailed specifications including dimensions, capacity, temperature, and electrical data for all chamber sizes.
| Interior Volume | 240 L |
|---|---|
| Number of Shelves | 2 |
| Max. Shelf Load | 30 kg |
| Voltage | 230 V |
| Frequency | 50/60 Hz |
| Temperature Range | 5 °C above ambient temperature to 300 °C |
| Power Consumption | 3.0 kW |