Issue 06/2014 Art. N0. 7001-0179
Operating Manual
APT.line™ KMF (E5.2)
Constant climate chambers
with enlarged temperature and humidity range
with program control
Model
Art. No.
KMF 115 (E5.2)
9020-0187, 9120-0187
KMF 115-UL (E5.2)
9020-0188, 9120-0188
KMF 240 (E5.2)
9020-0145, 9120-0145
9020-0219, 9120-0219
KMF 240-UL (E5.2)
9020-0182, 9120-0182
KMF 720 (E5.2)
9020-0185, 9120-0185
9020-0245, 9120-0245
KMF 720-UL (E5.2)
9020-0186, 9120-0186
BINDER GmbH
Address Post office box 102
D-78502 Tuttlingen
Tel. +49 7462 2005 0
Fax +49 7462 2005 100
Internet http://www.binder-world.com
E-mail info@binder-world.com
Service Hotline +49 7462 2005 555
Service Fax +49 7462 2005 93 555
Service E-Mail service@binder-world.com
Service Hotline USA +1 866 885 9794 or +1 631 224 4340 x3
Service Hotline Asia Pacific +852 390 705 04 or +852 390 705 03
Service Hotline Russia and CIS +7 495 988 15 16

Table of Contents

Questions and Answers

  • E
    Eddie BoyerSep 8, 2025
    Why is there condensation at the walls of the inner chamber in my Binder Laboratory Equipment?
    • B
      Brittany CruzSep 8, 2025
      If you observe condensation at the walls of the inner chamber of your Binder Laboratory Equipment, it could be due to a combination of temperature/humidity values not being in the optimum range; select a combination of temperature/humidity values in the optimum range. Alternatively, the set-point may have been too long below ambient temperature, causing icing in the preheating chamber; defrost the unit.
  • S
    Sara RichmondSep 7, 2025
    Why is the refrigerating performance low in my Binder KMF-240-UL Laboratory Equipment?
    • M
      Maria HillSep 7, 2025
      If you are experiencing low or no refrigerating performance in your Binder Laboratory Equipment, it could be due to several reasons. The ambient temperature might be higher than 25 °C / 77 °F, in which case you should select a cooler place of installation. It could also be that the combination of temperature/humidity values is not in the optimum range; select a combination of temperature/humidity values in the optimum range. If the compressor is not turned on, contact BINDER service. Also, too much external heat load could be the cause, so reduce heat load.
  • M
    martinpatriciaAug 22, 2025
    What to do if my Binder KMF-240-UL Laboratory Equipment chamber doesn’t heat up when turned on and the safety controller responds?
    • C
      Chase CallahanAug 22, 2025
      If your Binder Laboratory Equipment unit isn't heating up when turned on and the safety controller responds, it could be due to the limit temperature being reached. The safety controller might be set too low. To fix this, let the chamber cool down and hit the RESET button of the MB1 controller. If appropriate, select a suitable limit value. If the safety controller is defective, contact BINDER service.
  • K
    Kyle HallSep 4, 2025
    What to do if mechanical safety device class 3.2 responds in my Binder KMF-240-UL Laboratory Equipment?
    • L
      lhunterSep 4, 2025
      If the mechanical safety device class 3.2 responds in your Binder Laboratory Equipment (with option safety device class 3.3), it could be because the limit temperature has been reached. Check the setting of the temperature set-point and of safety device class 3.2. If appropriate, select a suitable limit value. If the controller or safety device is defective, contact BINDER service.
  • S
    Susan BeckerSep 3, 2025
    What to do if mechanical safety device class 3.1 responds in my Binder Laboratory Equipment?
    • S
      Sara FrancoSep 3, 2025
      If the mechanical safety device class 3.1 responds in your Binder Laboratory Equipment (with option safety device class 3.3), it might be because the limit temperature has been reached. Check the setting of the temperature set-point and of safety device class 3.1. If appropriate, select a suitable limit value. Also, too much external heat load could be the cause, so reduce the heat load. If the controller is defective, contact BINDER service.
  • S
    Steven SantiagoSep 1, 2025
    Why my Binder KMF-240-UL has no function?
    • R
      Renee CoxSep 1, 2025
      If your Binder Laboratory Equipment unit has no function at all, start by checking the connection to the power supply. Also, verify that the power supply voltage matches the unit's requirement of 115V or 230V. Inspect the unit fuse and replace it if necessary. If the fuse responds again, contact BINDER service. A defective controller may also cause this issue, requiring you to contact BINDER service.
  • A
    Ashley FrenchAug 31, 2025
    What to do if my Binder KMF-240-UL has no unit function and a dark display?
    • B
      Brett AyersAug 31, 2025
      If your Binder Laboratory Equipment unit shows no function with a dark display, it could be due to the display mode being in “Standby”. To resolve this, simply press any controller key. Alternatively, the main power switch might be turned off; in that case, turn on the main power switch.
  • J
    jbrownAug 30, 2025
    Why am I getting a humidity alarm message when operating without humidity on my Binder Laboratory Equipment?
    • A
      Adam BarrAug 30, 2025
      If you receive a humidity alarm message when operating without humidity (humidity switch (4) OFF) on your Binder Laboratory Equipment, it means that the humidity set-point is set to a value > 0% r.F. In Manual Mode: Enter a humidity set-point 0% r.H. In Program Mode: Enter a humidity subprogram with humidity set-point 0% r.H.
  • A
    Adam WhiteAug 28, 2025
    How to fix low humidity and temperature accuracy in Binder KMF-240-UL?
    • S
      Samantha HensleyAug 29, 2025
      If you're experiencing low humidity and temperature accuracy with your Binder Laboratory Equipment, it might be because the fan speed has been reduced. Set the fan speed to 100%.
  • B
    brianna75Aug 27, 2025
    Why does my Binder KMF-240-UL have humidity fluctuation?
    • M
      Michael JamesAug 27, 2025
      If you're experiencing humidity fluctuation and the control accuracy of ± 3 % r.F. is not reached in your Binder Laboratory Equipment, it could be due to a defective door gasket; replace the door gasket. Also, opening the door very frequently can cause this issue; try to open the doors less frequently.

Summary

Safety

General Installation & Operation Safety

General safety rules for installation and operation.

Intended Use

Defines the proper applications and limitations of the unit.

Unit Description

Completeness, Transportation, Storage, Installation

Safe Lifting and Transportation

Instructions for safely moving and transporting the unit.

Installation Site & Ambient Conditions

Requirements for the installation site and environmental conditions.

Installation and Connections

Electrical Connection

Instructions for connecting the unit to the power supply.

Start Up

Operating Modes

Explains the different operating modes (Idle, Manual, Program).

MB1 Controller Settings

Historical Measurement (Chart Recorder)

Manual Mode

Entering Set Point Values

Steps to input temperature and humidity set points.

Program Operation

Menu-Based Program Entry

How to create programs using the controller menu.

Entry of Temperature and Fan Speed

Details entering temperature and fan speed into program tables.

Entry of Humidity Values

Details entering humidity values into program tables.

Set-Point Ramp vs. Set-Point Step

Explains ramp vs. step programming methods.

Program Entry Examples

Examples of entering ramp and step program types.

Programming Transition Information

Tips and rules for programming transitions.

Temperature Safety Devices

Over-Temperature Protective Device (Class 1)

Describes the primary over-temperature protection.

Safety Controller (Class 3.1)

Explains the secondary safety controller for over-temperature.

Safety Controller Set-Point Types

Defines 'Limit' and 'Offset' types for the safety controller.

Checking and Setting Safety Controller

Guides on checking and configuring the safety controller.

Optional Class 3.3 Safety Device

Details the optional combined safety device class 3.3.

Class 3.1 Safety Device Operation

Instructions for setting and checking the class 3.1 safety device.

Class 3.2 Safety Device Operation

Instructions for setting and checking the class 3.2 safety device.

Notification and Alarm Functions

Alarm System Overview

Overview of the unit's notification and alarm system.

Resetting Notifications and Alarms

Procedures for acknowledging and clearing alarms.

Humidity System

Humidifying;Dehumidifying System Function

Explains how the humidification and dehumidification systems work.

Maintenance, Cleaning, and Service

Maintenance Intervals and Service

Recommended schedules for maintenance and service.

Cleaning and Decontamination

Procedures for cleaning and decontaminating the unit.

Cleaning Procedures

Detailed steps for cleaning internal and external surfaces.

Decontamination Procedures

Procedures for decontaminating hazardous material contamination.

Troubleshooting

Heating Issues

Solutions for problems related to chamber heating functions.

Refrigeration Performance Issues

Troubleshooting for low or no refrigeration.

Controller Issues

Addresses issues with the MB1 controller display and functions.

Binder KMF-240-UL Specifications

General IconGeneral
ModelKMF-240-UL
CategoryLaboratory Equipment
TypeConstant Climate Chamber
Temperature Range-10 °C to 100 °C
Volume240 liters
Power Supply230 V