EasyManua.ls Logo

Binder BD 56 - User Manual

Binder BD 56
117 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Issue 02/2022 Art. No. 7001-0292
Operating Manual
BD (E3.1)
|
Incubators
Avantgarde.Line with natural convection
BF (E3.1)
|
Incubators
Avantgarde.Line with forced convection
ED (E3.1)
|
Drying and heating ovens
Avantgarde.Line with natural convection
FD (E3.1)
|
Drying and heating ovens
Avantgarde.Line with forced convection
FED (E3.1)
|
Drying and heating ovens
Avantgarde.Line with forced convection
and enhanced timer functions
with microprocessor temperature controller
Model Model version Art. No. Model Model version Art. No.
BD 56
BD056-230V 9010/ 9110-0323
ED 260
ED260-230V 9010/ 9110-0339
BD056UL-120V 9010/ 9110-0324 ED260UL-240V 9010/ 9110-0340
BD 115
BD115-230V 9010/ 9110-0325 ED 720 ED720-400V 9010/ 9110-0341
BD115UL-120V 9010/ 9110-0326
FD 56
FD056-230V 9010/ 9110-0303
BD 260
BD260-230V 9010/ 9110-0329 FD056UL-120V 9010/ 9110-0304
BD260UL-120V 9010/ 9110-0330
FD 115
FD115-230V 9010/ 9110-0305
BD 720
BD720-230V 9010/ 9110-0331 FD115UL-120V 9010/ 9110-0306
BD720UL-240V 9010/ 9110-0332
FD 260
FD260-230V 9010/ 9110-0309
BF 56
BF056-230V 9010/ 9110-0313 FD260UL-240V 9010/ 9110-0310
BF056UL-120V 9010/ 9110-0314 FD 720 FD720-400V 9010/ 9110-0311
BF 115
BF115-230V 9010/ 9110-0315
FED 56
FED056-230V 9010/ 9110-0295
BF115UL-120V 9010/ 9110-0316 FED056UL-120V 9010/ 9110-0296
BF 260
BF260-230V 9010/ 9110-0319
FED 115
FED115-230V 9010/ 9110-0293
BF260UL-120V 9010/ 9110-0320 FED115UL-120V 9010/ 9110-0294
BF 720
BF720-230V 9010/ 9110-0321
FED 260
FED260-230V 9010/ 9110-0299
BF720UL-240V 9010/ 9110-0322 FED260UL-240V 9010/ 9110-0300
ED 56
ED056-230V 9010/ 9110-0333
FED 720
FED720-400V 9010/ 9110-0301
ED056UL-120V 9010/ 9110-0334 FED720UL-208V 9010/ 9110-0302
ED 115
ED115-230V 9010/ 9110-0335
ED115UL-120V 9010/ 9110-0336
BINDER GmbH
Address: Post office box 102, 78502 Tuttlingen, Germany Phone: +49 7462 2005 0
Fax: +49 7462 2005 100 Internet: http://www.binder-world.com
E-mail: info@binder-world.com Service Hotline: +49 7462 2005 555
Service Fax: +49 7462 2005 93 555 Service E-Mail: customerservice@binder-world.com
Service Hotline USA: +1 866 885 9794 or +1 631 224 4340 x3
Service Hotline Asia Pacific: +852 390 705 04 or +852 390 705 03
Service Hotline Russia and CIS: +7 495 988 15 16

Table of Contents

Questions and Answers

Summary

Safety

Personnel Qualification

Describes required qualifications for safe operation of the chamber.

Operating Manual

Highlights the importance of the manual for safe and correct use.

Legal Considerations

General legal notes pertaining to the operation and use of the chamber.

Structure of the Safety Instructions

Explains safety symbols, signal words, and hazard communication structure.

Localization of Safety Labels

Identifies where safety labels are placed on the chamber for easy reference.

Type Plate

Details the information presented on the device's identification and specification plate.

General Safety Instructions

Crucial safety guidelines for installation and operation of the chambers.

Intended Use

Defines the proper usage of the chamber to avoid operational risks.

Foreseeable Misuse

Lists actions considered improper and dangerous, posing risks despite safety features.

Residual Risks

Outlines inherent risks that cannot be eliminated even with safety measures.

Chamber Description

Chamber Overview

Provides a visual and functional overview of the chamber's main components.

Triangular Instrument Panel

Details the control interface, including display, buttons, and optional lighting switch.

Main Power Switch

Location and function of the main power switch for ED, FD, and FED 720 models.

Completeness of Delivery, Transportation, Storage, and Installation

Unpacking and Checking

Procedure for verifying delivery contents and checking for transportation damage.

Safe Lifting and Transportation

Critical safety instructions for moving the equipment during transport.

Storage Guidelines

Guidelines for storing the chamber before installation, including temperature and humidity.

Installation Location and Ambient Conditions

Requirements for the installation environment and ambient conditions.

Installation

Mounting Tilt Protection Holders

Instructions for installing safety hardware to prevent tipping, especially for chambers with windows.

Electrical Connection

Essential steps for powering the device safely and correctly, including voltage and fuse details.

Exhaust;Ventilation System Connection

Guidance for optional connection to an exhaust or ventilation system.

Inserting the Racks

Correct procedures for placing standard and heavy load racks inside the chamber.

Start Up

Behavior When Opening the Door

Describes how opening the door affects chamber operation and heating.

Performance During and After Power Failures

Explains how power interruptions affect device function and recovery.

Loading Procedures

Proper procedures for loading the chamber with materials, observing load limits.

Overview and General Settings on the R4 Controller

Controller Overview

Introduction to the controller interface, buttons, status symbols, and display.

Normal Display

Explanation of the standard display modes for chambers with and without adjustable fan speed.

Setting Menu Language

Step-by-step guide on how to change the controller's display language.

Setting Date and Time

Procedure for configuring the internal date and time settings of the controller.

Selecting Temperature Unit

How to switch between Celsius and Fahrenheit units for temperature display.

Set-Point Entry for Temperature and Fan Speed

How to set operational parameters like temperature and fan speed.

Set-Point Entry for Two-Door Chambers

Specific set-point rules for dual-door models based on ambient temperature.

Adjusting Air Flap Position

Control over the airflow and air change rate by adjusting the exhaust air flap.

Changing Passwords

Managing access control through password settings for user and controller functions.

Overtemperature Protection

Overtemperature Protective Device (Class 1)

Details on the primary overtemperature safety mechanism and its cut-off values.

Safety Controller

Explanation of secondary safety control systems (class 2 & 3.1) for temperature protection.

Setting Safety Controller Set-Point

How to configure the safety controller's limit temperature value.

Alarm Message and Alarm Handling

How to handle and respond to overtemperature alarms and messages.

Function Check for Safety Devices

Recommended checks to ensure safety features are operational.

Disconnectable Audible Over-Temperature Alarm

Configuration of an optional audible alarm for overtemperature events.

Timer Functions

Selecting the Timer Function

Overview of available timer modes: Delayed Off, Temp. dependent Delayed Off, Delayed On.

Timer Function “Delayed Off”

Details on setting up delayed shutdown timers and fan operation.

Entry and Activation of Timer Run-Time

Step-by-step guide for configuring delayed off timers and fan settings.

Turning Off or Changing Timer Settings

How to manage active delayed off timers, including stopping or modifying them.

Temperature Dependent Delayed Off Timer

Timer function that starts based on reaching a specified temperature threshold.

Entry and Activation of Temp. Dependent Timer

Configuration steps for temperature-dependent timers, including run-time and set-point.

Turning Off or Changing Temp. Dependent Timer

How to manage active temperature-dependent timers.

Timer Function “Delayed On”

Timer function for delayed start of heating, including fan speed settings.

Entry and Activation of Delayed On Timer

Configuration steps for delayed on timers, including run-time and fan speed.

Changing Settings for Delayed On Timer

How to manage active delayed on timers.

Temperature Programming Example

Practical example demonstrating the use of timer functions for temperature programming.

Ramp Function

General Information on Ramp Function

Explanation of the ramp function's purpose, use, and limitations for temperature control.

Setting and Displaying the Ramp Function

How to program and view temperature ramp settings, including gradient and target set-point.

Displaying and Changing Effective Ramp Set-Point

Monitoring and adjusting ramp parameters during operation.

Turning Off the Ramp Function

How to disable the ramp feature by setting the gradient to zero.

Data Recording via USB Interface

Starting Data Recording

Steps to initiate data logging onto a USB stick, including setting the interval.

Terminating Data Recording

Steps to stop and save logged data from the USB interface.

Network Configuration for Chambers with Ethernet Interface

Options

APT-COM 4 Multi Management Software

Details on the optional software for chamber management and data acquisition.

Object Temperature Display with Pt100 Sensor

Description of the optional temperature sensor for monitoring samples or chamber contents.

Analog Output for Temperature

Information on the optional analog output (4-20 mA) for data registration systems.

HEPA Fresh Air Filter

Details on the optional HEPA filter for air purification in FD and FED models.

Water Protected Internal Socket

Description of the optional water-protected internal socket for BD and BF models.

Mostly Gas-Tight Version

Information on the optional gas-tight sealing for specific applications (BF, FD, FED).

Inert Gas Connection

Details on the optional inert gas connection for gas-tight versions (BF, FD, FED).

Cleaning and Decontamination

Cleaning Procedures

Procedures for regular cleaning of chamber surfaces and components using approved agents.

Decontamination and Chemical Disinfection

Procedures for disinfecting the chamber after contamination with hazardous substances.

Maintenance and Service, Troubleshooting, Repair, Testing

General Information and Personnel Qualification

Overview of service requirements and necessary qualifications for personnel.

Maintenance Intervals and Service

Recommended schedule for regular maintenance to ensure optimal performance.

Simple Troubleshooting

Guide for resolving common issues without specialized intervention.

Sending the Chamber Back to BINDER GmbH

Procedure for returning the unit for repair or service, including RMA requirements.

Disposal

Disposal of Transport Packing

Instructions for proper disposal of packaging materials.

Decommissioning

Steps to safely shut down and prepare the chamber for disposal.

Disposal in Germany

Specific disposal procedures for the chamber in the Federal Republic of Germany.

Disposal in EU Member States (excluding Germany)

Disposal procedures for the chamber in other EU member states.

Disposal in Non-Member States of the EU

Disposal procedures for the chamber in countries outside the European Union.

Technical Description

Factory Calibration and Adjustment

Information on initial calibration and adjustment processes performed at the factory.

Definition of Usable Volume

Explanation of how usable volume is calculated based on internal dimensions and wall clearances.

Over Current Protection

Details on safety mechanisms protecting against overcurrent, including fuses and circuit breakers.

BD Technical Data

Specific technical specifications for the BD model series, including dimensions and electrical data.

BF Technical Data

Specific technical specifications for the BF model series, including dimensions and electrical data.

ED Technical Data

Specific technical specifications for the ED model series, including dimensions and electrical data.

FD Technical Data

Specific technical specifications for the FD model series, including dimensions and electrical data.

FED Technical Data

Specific technical specifications for the FED model series, including dimensions and electrical data.

Equipment and Options

Lists standard equipment and available optional features for the chambers.

Accessories and Spare Parts

Information on purchasable accessories and replacement parts with article numbers.

Dimensions Size 56

Dimensional drawings and measurements for chamber models of size 56.

Dimensions Size 115

Dimensional drawings and measurements for chamber models of size 115.

Dimensions Size 260

Dimensional drawings and measurements for chamber models of size 260.

Dimensions Size 720

Dimensional drawings and measurements for chamber models of size 720.

Certificates and Declarations of Conformity

EU Declaration of Conformity for BD

CE conformity statement for BD model series, confirming compliance with EU directives.

EU Declaration of Conformity for BF

CE conformity statement for BF model series, confirming compliance with EU directives.

EU Declaration of Conformity for ED

CE conformity statement for ED model series, confirming compliance with EU directives.

EU Declaration of Conformity for FD

CE conformity statement for FD model series, confirming compliance with EU directives.

EU Declaration of Conformity for FED

CE conformity statement for FED model series, confirming compliance with EU directives.

GS Mark of Conformity Certificate (VDE)

GS mark conformity certificate from VDE Testing and Certification Institute.

UL Certification Mark Compliance Certificate

UL certification compliance document from Underwriters Laboratories.

Contamination Clearance Certificate

For Chambers Outside USA and Canada

Form for clearing contamination for returns outside North America.

For Chambers in USA and Canada

Form for clearing contamination for returns within North America.

Summary

Safety

Personnel Qualification

Describes required qualifications for safe operation of the chamber.

Operating Manual

Highlights the importance of the manual for safe and correct use.

Legal Considerations

General legal notes pertaining to the operation and use of the chamber.

Structure of the Safety Instructions

Explains safety symbols, signal words, and hazard communication structure.

Localization of Safety Labels

Identifies where safety labels are placed on the chamber for easy reference.

Type Plate

Details the information presented on the device's identification and specification plate.

General Safety Instructions

Crucial safety guidelines for installation and operation of the chambers.

Intended Use

Defines the proper usage of the chamber to avoid operational risks.

Foreseeable Misuse

Lists actions considered improper and dangerous, posing risks despite safety features.

Residual Risks

Outlines inherent risks that cannot be eliminated even with safety measures.

Chamber Description

Chamber Overview

Provides a visual and functional overview of the chamber's main components.

Triangular Instrument Panel

Details the control interface, including display, buttons, and optional lighting switch.

Main Power Switch

Location and function of the main power switch for ED, FD, and FED 720 models.

Completeness of Delivery, Transportation, Storage, and Installation

Unpacking and Checking

Procedure for verifying delivery contents and checking for transportation damage.

Safe Lifting and Transportation

Critical safety instructions for moving the equipment during transport.

Storage Guidelines

Guidelines for storing the chamber before installation, including temperature and humidity.

Installation Location and Ambient Conditions

Requirements for the installation environment and ambient conditions.

Installation

Mounting Tilt Protection Holders

Instructions for installing safety hardware to prevent tipping, especially for chambers with windows.

Electrical Connection

Essential steps for powering the device safely and correctly, including voltage and fuse details.

Exhaust;Ventilation System Connection

Guidance for optional connection to an exhaust or ventilation system.

Inserting the Racks

Correct procedures for placing standard and heavy load racks inside the chamber.

Start Up

Behavior When Opening the Door

Describes how opening the door affects chamber operation and heating.

Performance During and After Power Failures

Explains how power interruptions affect device function and recovery.

Loading Procedures

Proper procedures for loading the chamber with materials, observing load limits.

Overview and General Settings on the R4 Controller

Controller Overview

Introduction to the controller interface, buttons, status symbols, and display.

Normal Display

Explanation of the standard display modes for chambers with and without adjustable fan speed.

Setting Menu Language

Step-by-step guide on how to change the controller's display language.

Setting Date and Time

Procedure for configuring the internal date and time settings of the controller.

Selecting Temperature Unit

How to switch between Celsius and Fahrenheit units for temperature display.

Set-Point Entry for Temperature and Fan Speed

How to set operational parameters like temperature and fan speed.

Set-Point Entry for Two-Door Chambers

Specific set-point rules for dual-door models based on ambient temperature.

Adjusting Air Flap Position

Control over the airflow and air change rate by adjusting the exhaust air flap.

Changing Passwords

Managing access control through password settings for user and controller functions.

Overtemperature Protection

Overtemperature Protective Device (Class 1)

Details on the primary overtemperature safety mechanism and its cut-off values.

Safety Controller

Explanation of secondary safety control systems (class 2 & 3.1) for temperature protection.

Setting Safety Controller Set-Point

How to configure the safety controller's limit temperature value.

Alarm Message and Alarm Handling

How to handle and respond to overtemperature alarms and messages.

Function Check for Safety Devices

Recommended checks to ensure safety features are operational.

Disconnectable Audible Over-Temperature Alarm

Configuration of an optional audible alarm for overtemperature events.

Timer Functions

Selecting the Timer Function

Overview of available timer modes: Delayed Off, Temp. dependent Delayed Off, Delayed On.

Timer Function “Delayed Off”

Details on setting up delayed shutdown timers and fan operation.

Entry and Activation of Timer Run-Time

Step-by-step guide for configuring delayed off timers and fan settings.

Turning Off or Changing Timer Settings

How to manage active delayed off timers, including stopping or modifying them.

Temperature Dependent Delayed Off Timer

Timer function that starts based on reaching a specified temperature threshold.

Entry and Activation of Temp. Dependent Timer

Configuration steps for temperature-dependent timers, including run-time and set-point.

Turning Off or Changing Temp. Dependent Timer

How to manage active temperature-dependent timers.

Timer Function “Delayed On”

Timer function for delayed start of heating, including fan speed settings.

Entry and Activation of Delayed On Timer

Configuration steps for delayed on timers, including run-time and fan speed.

Changing Settings for Delayed On Timer

How to manage active delayed on timers.

Temperature Programming Example

Practical example demonstrating the use of timer functions for temperature programming.

Ramp Function

General Information on Ramp Function

Explanation of the ramp function's purpose, use, and limitations for temperature control.

Setting and Displaying the Ramp Function

How to program and view temperature ramp settings, including gradient and target set-point.

Displaying and Changing Effective Ramp Set-Point

Monitoring and adjusting ramp parameters during operation.

Turning Off the Ramp Function

How to disable the ramp feature by setting the gradient to zero.

Data Recording via USB Interface

Starting Data Recording

Steps to initiate data logging onto a USB stick, including setting the interval.

Terminating Data Recording

Steps to stop and save logged data from the USB interface.

Network Configuration for Chambers with Ethernet Interface

Options

APT-COM 4 Multi Management Software

Details on the optional software for chamber management and data acquisition.

Object Temperature Display with Pt100 Sensor

Description of the optional temperature sensor for monitoring samples or chamber contents.

Analog Output for Temperature

Information on the optional analog output (4-20 mA) for data registration systems.

HEPA Fresh Air Filter

Details on the optional HEPA filter for air purification in FD and FED models.

Water Protected Internal Socket

Description of the optional water-protected internal socket for BD and BF models.

Mostly Gas-Tight Version

Information on the optional gas-tight sealing for specific applications (BF, FD, FED).

Inert Gas Connection

Details on the optional inert gas connection for gas-tight versions (BF, FD, FED).

Cleaning and Decontamination

Cleaning Procedures

Procedures for regular cleaning of chamber surfaces and components using approved agents.

Decontamination and Chemical Disinfection

Procedures for disinfecting the chamber after contamination with hazardous substances.

Maintenance and Service, Troubleshooting, Repair, Testing

General Information and Personnel Qualification

Overview of service requirements and necessary qualifications for personnel.

Maintenance Intervals and Service

Recommended schedule for regular maintenance to ensure optimal performance.

Simple Troubleshooting

Guide for resolving common issues without specialized intervention.

Sending the Chamber Back to BINDER GmbH

Procedure for returning the unit for repair or service, including RMA requirements.

Disposal

Disposal of Transport Packing

Instructions for proper disposal of packaging materials.

Decommissioning

Steps to safely shut down and prepare the chamber for disposal.

Disposal in Germany

Specific disposal procedures for the chamber in the Federal Republic of Germany.

Disposal in EU Member States (excluding Germany)

Disposal procedures for the chamber in other EU member states.

Disposal in Non-Member States of the EU

Disposal procedures for the chamber in countries outside the European Union.

Technical Description

Factory Calibration and Adjustment

Information on initial calibration and adjustment processes performed at the factory.

Definition of Usable Volume

Explanation of how usable volume is calculated based on internal dimensions and wall clearances.

Over Current Protection

Details on safety mechanisms protecting against overcurrent, including fuses and circuit breakers.

BD Technical Data

Specific technical specifications for the BD model series, including dimensions and electrical data.

BF Technical Data

Specific technical specifications for the BF model series, including dimensions and electrical data.

ED Technical Data

Specific technical specifications for the ED model series, including dimensions and electrical data.

FD Technical Data

Specific technical specifications for the FD model series, including dimensions and electrical data.

FED Technical Data

Specific technical specifications for the FED model series, including dimensions and electrical data.

Equipment and Options

Lists standard equipment and available optional features for the chambers.

Accessories and Spare Parts

Information on purchasable accessories and replacement parts with article numbers.

Dimensions Size 56

Dimensional drawings and measurements for chamber models of size 56.

Dimensions Size 115

Dimensional drawings and measurements for chamber models of size 115.

Dimensions Size 260

Dimensional drawings and measurements for chamber models of size 260.

Dimensions Size 720

Dimensional drawings and measurements for chamber models of size 720.

Certificates and Declarations of Conformity

EU Declaration of Conformity for BD

CE conformity statement for BD model series, confirming compliance with EU directives.

EU Declaration of Conformity for BF

CE conformity statement for BF model series, confirming compliance with EU directives.

EU Declaration of Conformity for ED

CE conformity statement for ED model series, confirming compliance with EU directives.

EU Declaration of Conformity for FD

CE conformity statement for FD model series, confirming compliance with EU directives.

EU Declaration of Conformity for FED

CE conformity statement for FED model series, confirming compliance with EU directives.

GS Mark of Conformity Certificate (VDE)

GS mark conformity certificate from VDE Testing and Certification Institute.

UL Certification Mark Compliance Certificate

UL certification compliance document from Underwriters Laboratories.

Contamination Clearance Certificate

For Chambers Outside USA and Canada

Form for clearing contamination for returns outside North America.

For Chambers in USA and Canada

Form for clearing contamination for returns within North America.

Binder BD 56 Specifications

General IconGeneral
BrandBinder
ModelBD 56
CategoryLaboratory Equipment
LanguageEnglish

Related product manuals