EasyManua.ls Logo

Binder BF 720 - User Manual

Default Icon
117 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Issue 02/2022 Art. No. 7001-0292
Operating Manual
BD (E3.1)
|
Incubators
Avantgarde.Line with natural convection
BF (E3.1)
|
Incubators
Avantgarde.Line with forced convection
ED (E3.1)
|
Drying and heating ovens
Avantgarde.Line with natural convection
FD (E3.1)
|
Drying and heating ovens
Avantgarde.Line with forced convection
FED (E3.1)
|
Drying and heating ovens
Avantgarde.Line with forced convection
and enhanced timer functions
with microprocessor temperature controller
Model Model version Art. No. Model Model version Art. No.
BD 56
BD056-230V 9010/ 9110-0323
ED 260
ED260-230V 9010/ 9110-0339
BD056UL-120V 9010/ 9110-0324 ED260UL-240V 9010/ 9110-0340
BD 115
BD115-230V 9010/ 9110-0325 ED 720 ED720-400V 9010/ 9110-0341
BD115UL-120V 9010/ 9110-0326
FD 56
FD056-230V 9010/ 9110-0303
BD 260
BD260-230V 9010/ 9110-0329 FD056UL-120V 9010/ 9110-0304
BD260UL-120V 9010/ 9110-0330
FD 115
FD115-230V 9010/ 9110-0305
BD 720
BD720-230V 9010/ 9110-0331 FD115UL-120V 9010/ 9110-0306
BD720UL-240V 9010/ 9110-0332
FD 260
FD260-230V 9010/ 9110-0309
BF 56
BF056-230V 9010/ 9110-0313 FD260UL-240V 9010/ 9110-0310
BF056UL-120V 9010/ 9110-0314 FD 720 FD720-400V 9010/ 9110-0311
BF 115
BF115-230V 9010/ 9110-0315
FED 56
FED056-230V 9010/ 9110-0295
BF115UL-120V 9010/ 9110-0316 FED056UL-120V 9010/ 9110-0296
BF 260
BF260-230V 9010/ 9110-0319
FED 115
FED115-230V 9010/ 9110-0293
BF260UL-120V 9010/ 9110-0320 FED115UL-120V 9010/ 9110-0294
BF 720
BF720-230V 9010/ 9110-0321
FED 260
FED260-230V 9010/ 9110-0299
BF720UL-240V 9010/ 9110-0322 FED260UL-240V 9010/ 9110-0300
ED 56
ED056-230V 9010/ 9110-0333
FED 720
FED720-400V 9010/ 9110-0301
ED056UL-120V 9010/ 9110-0334 FED720UL-208V 9010/ 9110-0302
ED 115
ED115-230V 9010/ 9110-0335
ED115UL-120V 9010/ 9110-0336
BINDER GmbH
Address: Post office box 102, 78502 Tuttlingen, Germany Phone: +49 7462 2005 0
Fax: +49 7462 2005 100 Internet: http://www.binder-world.com
E-mail: info@binder-world.com Service Hotline: +49 7462 2005 555
Service Fax: +49 7462 2005 93 555 Service E-Mail: customerservice@binder-world.com
Service Hotline USA: +1 866 885 9794 or +1 631 224 4340 x3
Service Hotline Asia Pacific: +852 390 705 04 or +852 390 705 03
Service Hotline Russia and CIS: +7 495 988 15 16

Table of Contents

Other manuals for Binder BF 720

Questions and Answers

Summary

1. Safety

1.1 Personnel Qualification

Requirements for qualified personnel to install, test, and operate the chamber safely.

1.4 Structure of Safety Instructions

Explains safety definitions, signal words, safety alert symbols, and pictograms used in the manual.

1.7 General Safety Instructions

Provides general safety guidelines for chamber installation, operation, and ventilation.

2. Chamber Description

3. Delivery, Transportation, Storage, and Installation

3.2 Safe Lifting and Transportation Guidelines

Provides essential guidelines and cautions for safely lifting and transporting the chamber.

4. Installation

4.2 Electrical Connection

Details the electrical connection requirements and specifications for various chamber models.

5. Start Up

6. Overview and Settings on R4 Controller

6.6 Set-point Entry for Temperature and Fan Speed

Instructions for entering temperature and fan speed set-points on the controller.

7. Overtemperature Protection

7.2 Safety Controller

Details the adjustable safety controller (class 2 or 3.1) for temperature protection.

7.3 Setting Safety Controller Set-point

Guide to setting the safety controller's limit temperature set-point.

7.4 Alarm Message and Procedures

Describes alarm messages and procedures for resetting alarms for class 2 and 3.1 controllers.

8. Timer Functions

8.2 Timer Function Delayed Off

Entry and activation of the timer run-time and fan setting for "Delayed Off" function.

9. Ramp Function

10. Data Recording via USB Interface

11. Network Configuration for Ethernet Interface

13. Cleaning and Decontamination

13.2 Decontamination; Chemical Disinfection

Steps for proper decontamination and chemical disinfection of the chamber in case of contamination.

14. Maintenance, Service, Troubleshooting, and Repair

14.3 Simple Troubleshooting

Table listing common faults, possible causes, and required troubleshooting measures.

Summary

1. Safety

1.1 Personnel Qualification

Requirements for qualified personnel to install, test, and operate the chamber safely.

1.4 Structure of Safety Instructions

Explains safety definitions, signal words, safety alert symbols, and pictograms used in the manual.

1.7 General Safety Instructions

Provides general safety guidelines for chamber installation, operation, and ventilation.

2. Chamber Description

3. Delivery, Transportation, Storage, and Installation

3.2 Safe Lifting and Transportation Guidelines

Provides essential guidelines and cautions for safely lifting and transporting the chamber.

4. Installation

4.2 Electrical Connection

Details the electrical connection requirements and specifications for various chamber models.

5. Start Up

6. Overview and Settings on R4 Controller

6.6 Set-point Entry for Temperature and Fan Speed

Instructions for entering temperature and fan speed set-points on the controller.

7. Overtemperature Protection

7.2 Safety Controller

Details the adjustable safety controller (class 2 or 3.1) for temperature protection.

7.3 Setting Safety Controller Set-point

Guide to setting the safety controller's limit temperature set-point.

7.4 Alarm Message and Procedures

Describes alarm messages and procedures for resetting alarms for class 2 and 3.1 controllers.

8. Timer Functions

8.2 Timer Function Delayed Off

Entry and activation of the timer run-time and fan setting for "Delayed Off" function.

9. Ramp Function

10. Data Recording via USB Interface

11. Network Configuration for Ethernet Interface

13. Cleaning and Decontamination

13.2 Decontamination; Chemical Disinfection

Steps for proper decontamination and chemical disinfection of the chamber in case of contamination.

14. Maintenance, Service, Troubleshooting, and Repair

14.3 Simple Troubleshooting

Table listing common faults, possible causes, and required troubleshooting measures.

Binder BF 720 Specifications

General IconGeneral
Temperature Range5 °C above ambient temperature to 300 °C
Interior Volume720 liters
Nominal Voltage230 V
Voltage230 V
Door Opening (W x H)1000 x 1200 mm
Heat-up time to 150°Capprox. 30 min
Number of Shelves (standard/max)2/

Related product manuals