Safety
Information
Notice
to
Purchaser
Purchase
of
this
instrument,
Serial
No.
,
conveys
a
limited
non-transfer
able
immunity
from
suit
for
the
purchaser's
own
internal
research
and
development
and
for
use
in
applied
fields
other
than
Human
In
Vitro
Diagnostics
under
one
or
more
of
U.S.
Patents
Nos.
5,656,493, 5,333,675,
5,475,610
(claims
1,
44,
158,
160-163
and
167
only),
and
6,703,236
(claims
1-7
only),
or
corresponding
claims
in
their
non-U.S.
counterparts,
owned
by
Applera
Corporation.
No
right
is
conveyed
expressly,
by
implication
or
by
estop
pel
under
any
other
patent
claim,
such
as
claims
to
apparatus,
reagents,
kits,
or
methods
such
as
5'
nuclease
methods.
Further
information
on
purchasing
licenses
may
be
obtained
by
contacting
the
Director of
Licensing,
Applied
Biosystems,
850
Lincoln
Centre
Drive,
Foster
City,
California
94404,
USA.
The
sample
block
of
the
MyCycler
thermal
cycler
can
reach
temperatures
of
100°C,
and
the
heated
lid
can
be
programmed
to
maintain
temperatures
up
to
110°C.
The
heated
lid
should
remain
closed
at
all
times
during
operation
to
prevent
accidental
skin
burns.
Always
allow
the
sample
block
to
return
to
its
idle
temperature
before
opening
the
lid
and
removing
samples.
When
placing
or
removing
samples,
open
the
heated
lid
all
the
way
up
to
allow
maximum
clearance
and
to
avoid
accidental
skin
burns.
This
symbol
on
the
reaction
module
indicates
a
hot
surface.
Always
connect
the
power
supply
to
a
3-prong,
grounded
AC
outlet
rated
10
A/100-120
V
or
5
A/220-240
V
using
the
AC
power
cord provided
with
the
MyCycler.
Do
not
use
an
adapter
to
a
two-terminal
outlet.
Before
plugging
the
instrument
in,
be
sure
that
the
correct
fuse
is
installed
in
the
rear
panel
fuse
holder.
Use
the
4A
5
x
20
mm
TYPE
T
fuse
for
220-240
V
or
the
8A
5 x
20
mm
TYPE
T
fuse
for
100-120
V.
Never
remove
the
outer
casing
of
the
MyCycler.
There
are
no
user-serviceable
parts
for
this
instrument.
Call
your
local
Bio-Rad
office
for
instrument
services.
To
insure
adequate
cooling
of
the
MyCycler,
place
it
on
a
clean,
flat
surface,
and be
sure
that
there
is
at
least
4
inches
(10
cm)
clearance
around
each
side
of
the
thermal
cycler.
Make
sure
that
the
bench space
is
free
of
any
foreign
objects
or
debris
that
could
block
the
fan
vents.
Do
not
operate
the
MyCycler
in
extreme
humidity
or
where
condensation
can
short
the
internal
electrical
circuits
of
the
thermal
cycler.
Notice
This
Bio-Rad
instrument
is
designed
and
certified
to
meet
EN-61010
safety
standards.
EN-61010
certified
products
are
safe
to
use
when
operated
in
accordance
with
the
instruction
manual.
This
instrument
should
not
be
modified
in
any
way.
Alteration
of
this
instrument
will:
Void
the
manufacturer's
warranty,
Void
the
EN-61010
safety
certification,