ML0038 September 27, 2017 - 15 - Copyright 2017 Bitronics, LLC
Environmental
Operating Temperature -40C to 70C
Relative Humidity 0-95% non-condensing
Measurement Inputs
(VTs, CTs)
Installation/Measurement
Cate
g
or
y
CAT III (Distribution Level) Refer to definitions below.
Pollution Degree Pollution Degree 2 Refer to definitions below.
Enclosure Protection
(to IEC60529: 2001)
Front Panel: IP 20, Rear: IP 20
When equipment is mounted in an appropriately rated protective enclosure to NEMA or IP
protection classifications, as required for the installation. Ratings are applicable for enclosure
cate
g
or
y
2
(
see definitions
)
Altitude Up to and including 2000m above sea level
Intended Use Indoor use; Indoor/Outdoor use when mounted in an appropriately rated protective enclosure
to NEMA or IP protection classifications, as required for the installation.
Class 1 equipment to IEC61140: 2001