Why is my Bizerba SC II 800 printer not printing?
- KKristina GarrettAug 26, 2025
If your Bizerba Scales printer won't print, it might be because the print bar is open. Make sure to close the print bar correctly.
Why is my Bizerba SC II 800 printer not printing?
If your Bizerba Scales printer won't print, it might be because the print bar is open. Make sure to close the print bar correctly.
How to fix Bizerba SC II 800 display if it does not illuminate?
If the display of your Bizerba Scales does not illuminate, the issue might be due to a lack of supply voltage or incorrect display settings. First, ensure the power cable is properly connected and the mains switch is turned on. If the display remains dark, reset the display settings by confirming the key sequence: +.
What does 'Apply weight' mean on Bizerba SC II 800?
If your Bizerba Scales display 'Apply weight' during sales, registration is only performed for a weight-dependent PLU after a load change.
What does 'No ticket data existing' mean on Bizerba SC II 800?
If your Bizerba Scales display 'No ticket data existing' during sales when entering the ticket no. with the 'Enter ticket no.' key, check that the entered ticket no. is correct and re-enter it.
What does 'No overwriting' mean on Bizerba SC II 800?
If your Bizerba Scales display 'No overwriting' during sales, it means the PLU is locked in PLU maintenance for price overwriting. Switch on price overwrite.
What does 'No extra text under this number!' mean on Bizerba SC II 800 Scales?
If your Bizerba Scales display 'No extra text under this number!' during sales when calling a general text with the 'Call gen. text' key, check the entered text number. Also, in the 'Data maintenance' / 'Texts' / 'Gen. texts' menu, check the entry for the applied text number.
What does 'Cashier has not determined a Cash reg. (POS) act.!' mean on Bizerba Scales?
If your Bizerba Scales display 'Cashier has not determined a Cash reg. (POS) act.!' for cashier reports, in 'Configuration', the setting 'Compulsory cash reg. POS act.' must be set in the 'Cash reg.' menu.
What to do if Bizerba Scales display 'Cash drawer X is not connected'?
If your Bizerba Scales display 'Cash drawer X is not connected' in cash register mode, check the set values of the operator used in 'Data maintenance' / 'Operator data'. Also, check the SC II connection cable for the cash drawer.
What does 'Preset tare error' mean on Bizerba SC II 800 Scales?
If your Bizerba Scales display 'Preset tare error' during sales, it means when entering a known tare, the tare value may not exceed the lower division range on a two-interval scale. Enter the tare in the lower division range only.
What does 'Unit price too large' mean on Bizerba SC II 800 Scales?
If your Bizerba Scales display 'Unit price too large' during sales, check the settings for sales limits in 'Configuration' / 'Device settings' / 'Sales limits'.
| Application | Retail |
|---|---|
| Display | LCD with backlight |
| Interfaces | Ethernet, RS-232 |
| Operating System | Linux |
| Power supply | 110-240 V AC, 50/60 Hz |
Details danger levels (DANGER, WARNING, CAUTION, NOTICE) and their meanings.
Specifies the device's purpose as a high-quality system scale for counter sales.
Details metrological requirements and verification procedures for EU and non-EU countries.
Outlines essential operating conditions like temperature, humidity, installation surface, and power supply.
Details the requirements for connecting the device to a power source.
Identifies potential hazards related to the system, including electrical risks.
Specifies necessary training and responsibilities for personnel operating the device.
Guides through the physical installation, including leveling and connections.
Instructions for verifying the electrical connections before powering on.
Explains the configuration and standard functions of various keys.
Step-by-step instructions for powering on the scale and initial display.
Specific operating procedures for the SC II 100 K/B model, including sales settings.
Covers methods for retrieving product data (PLU) for sales.
Details the steps following a PLU call-up, including registration and unit price input.
Describes how to manually enter weight for "weighed" product types.
Steps for selling items without using PLU call-up, involving manual price input.
Procedures for canceling articles before finishing a sale.
Comprehensive section on tare functions, including balancing and known tare.
How to weigh and apply tare for unknown containers or items.
Procedures for entering and using known tare values.
Using tare values associated with specific PLUs.
Operating the scale in a self-service mode for customer transactions.
Using the scale as a cash register, including pay-in/pay-out and cashier functions.
Managing articles with various pricing methods like graduated prices or discounts.
Applying discounts or free items based on quantity thresholds.
Applying discounts based on total amount thresholds.
Ensuring piece count is entered for specific article types.
Handling articles with fixed prices based on weight, with various PLU types.
Lists common faults, their possible causes, and recommended solutions.
Explains various text messages, their causes, and remedies for error rectification.
General instructions and safety precautions for cleaning the device.
Detailed steps and warnings for cleaning the scale itself.
Procedures for cleaning the printer components, including the thermal strip.