8
- RESISTANCE
Range Resolution Accuracy Over Load Protection
2 KO
20 KO
200 KO
2 MO
0.1 O
1 O
10 O
100 O
±(0.2% + 5d)
20 MO 1 KO ±(1% + 10d)
600V DC or Peak
- FREQUENCY
Range Resolution Accuracy Over Load Protection
20 KHz 1 Hz ±(1.0% + 5d)
200 kHz 10 Hz ±(2.0% + 5d)
600V DC or Peak
* The digit error(less than 5digits) is added in measuring value.
- AUDIBLE CONTINUITY
Test Volt Threshold Over Load Protection
3V Less Than 200 ohm 600V DC or Peak
- DIODE TEST
Test Volt Max. Test Current Over Load Protection
2V Approx. 1.0 mA 600V DC or Peak
n DIMENSION AND WEIGHT
Dimensions HWD: 9.4 x 3.5 x 10.6” (240 x 90 x 270mm)
Weight Aprox : 4.6lb (2.1 kg.)
1-3. Equipment Ratings
l Plug and Socket : 3 wire ac power plug and 3 wire outlet
l Power & Fuse Ratings
Input Voltage Fuse Power Max.