4080 series Function & Arbitrary/Function Generators Instruction Manual
43
BM:SOURce?
Check current trigger source of burst.
BM:STATe {ON|OFF}
Turn on burst mode (ON) or turn off burst mode (OFF).
BM:STATe?
Check “on/off” state of burst mode. The returned data are “0 (OFF) or 1 (ON). The instrument
reverts back to fixed frequency mode in “off” state.
FSK Mode instructions
1To set the output waveform, amplitude, DC offset and frequency 1 using APPLy instructions or
FUNCtion, FREQuency, VOLTage, VOLTAGE:OFFSet instructions.
2set frequency 2 of FSK using FSKey: FREQuency <frequency> instruction.
3set time interval of frequency switching using FSKey:INTernal: SPACe <time> instruction.
4set trigger source of FSK using FSKey: SOURce {INTernal|EXTernal} instructions.
5turn on FSK using FSKey: STATe ON instruction.
FSKey:FREQuency <frequency>
Set frequency 2 of FSK.
FSKey:FREQuency?
Check frequency 2 of FSK.
FSKey:INTernal:SPACe <time>
Set time interval of frequency switching
FSKey:INTernal:SPACe?
Check time interval of frequency switching
FSKey:SOURce {INTernal|EXTernal}
Set trigger source of FSK as internal (INTernal) or external (EXTernal).
FSKey:SOURce?
Check current trigger source of FSK.
FSKey:STATe {ON|OFF}
Turn on FSK mode (ON) or turn off FSK mode (OFF).
FSKey:STATe?
Check the “on/off” state of FSK mode. The returned data are “0 (OFF) or 1 (ON). It returns to
fixed frequency mode in “off” state.
PSK Mode instructions
1. To set the output waveform, amplitude, DC offset and frequency using APPLy instructions or
FUNCtion, FREQuency, VOLTage, VOLTAGE:OFFSet instructions.
2. To set phase 1of PSK using PSKey: PHASe1 <degrees> instruction.
3. To set phase 2 of PSK using PSKey: PHASe2 <degrees> instruction.
4. To set time interval of phase switching using PSKey:INTernal: SPACe <time> instruction.
5. To set trigger source of PSK using PSKey: SOURce {INTernal|EXTernal} instructions.
6. To turn on PSK using PSKey: STATe ON instruction.
FSKey:PHASe1 <degrees>
Set phase 1 of PSK in 0--360º.
PSKey:PHASe1?
Check phase 1of PSK

Questions and Answers: