35
CHAPTER 4: Operation
To make the Spectra stop scanning, press and release
[Ctrl], then press and release [X]; you will have KVM
access to the CPU that was being scanned when you
entered the command. You can also stop scans by
entering a Select CPU command (see Section 4.2).
4.4 Stop/Restart Audio Switching
In its default setting, the ServSwitch Spectra switches
and scans the attached computers’ audio output along
with their video output and keyboard and mouse input.
In other words, when you select a CPU with [Ctrl] [1],
[Ctrl] [2], or [Ctrl] [Backspace], keyboard, mouse,
video, and audio access are all switched to that CPU;
and when you scan with [Ctrl] [S], the Spectra goes
back and forth between the two CPUs’ audio as well
as their keyboard, mouse, and video.
In some situations, such as when you are listening
to an audio CD or Web radio on one of the CPUs, you
might not want the audio to be switched or scanned
along with KVM access. If you want one of the CPUs
to be the uninterrupted audio source, you can enter a
“Stop Audio Switching” command: Press and release
the left Control key ([Ctrl]), then press and release [G],
then press and release that CPU’s number key at the top