26
CLEANING, CARE, MAINTENANCE
13.3 Heating-up time
It takes about 15 minutes for water to heat up during commissioning or when all the
hot water has been used up.
13.4 Data table
Technical data
Height (mm): 337
Diameter (mm): 229
Net weight (boiler + packaging): max. 4.8 kg
Total weight (lled boiler): about 8 kg
System pressure: 10 bar
Maximum pressure as per IEC 60335: 20 bar for 3 minutes
Minimum pressure in water inlet: 1 bar
Highest pressure in water inlet: 5 bar
Ambient temperature at installation location: 0 - 40 °C
Hot water temperature: 100 - 105 °C
Maximum temperature during normal operation: 105°C ± 1°C
Thermal safety shut-off: 124°C ± 3°C
Medium: drinking water
Power supply: 230 VAC, 50/60 Hz
Heat-up time (from 10°C to the maximum temperature): about 15 minutes
Power consumption: 2100 W (+ 5% / -10%)
Protection type as per EN 60529: IP X4
Stand-by losses (when switched on): max. 16 W
Stand-by losses (when switched off): max. 1 W
Energy efciency class: A
Material in supply tank: grade 2 titanium
Fill level: 4 litres (± 5%)
Flow rate at 99°C at the outlet: ≥ 2.5 litres
Designed for water quality: max. 12 °dTH
Filter type: BLANCO lter cartridge
Filter brand: BWT
Operation with designated BLANCO hot water mixer taps and the supplied safety
assembly module.
EN