GAS CONVECTION OVENS 5 INSTALLATION
DOUBLE SECTION ASSEMBLY - ES MODELS
1. Secure the short legs to the bottom sections as described.
2. Place the upper section in position on top of the lower oven.
3. Attach the stacking brackets using the remaining 5/16” bolts shipped with the ovens.
4. Attach the draft diverter to the bottom oven. DO NOT install the draft diverter guard on the bottom oven.
5. Install the ue riser on the top oven. The bottom of the ue riser slides down over the draft diverter on the bottom oven.
Secure with 12 screws.
6. Install the ue riser guard as shown below.
OVEN LEVELING
After assembly, the oven should be leveled and moved to the operating location.
1. The oven can be leveled by adjusting the feet or casters located on the bottom of each leg.
Flue Riser Guard
Flue Riser
Flue Riser
Draft Diverter
Stacking
Brackets
DFG-100-ES Shown
Figure 4
OVEN ASSEMBLY