V3A | 08/2018
26
© by Blum-Novotest
Configuration
Options
6 Flash
ON** Autoflash: Activation of probing system with intervis-
ibility
OFF * Flash by M-Code: Activation of probing system via
M-function M (Start)
7
Level-con-
trolled
ON Impulse-controlled via M-code
Activation / deactivation via impulse
signal, T > 10 ms
Condition: SW6 = OFF
OFF * Level-controlled via M-code
Activation / deactivation via level sig-
nal
Condition: SW6 = OFF
8 Auto ON
ON Reactivation by control (trigger signal)
OFF * Reactivation by interface (trigger signal)
On interruption of the transmission, the interface
tries to reactivate the probing system.
9
Mode
switch-
over
ON** Mode DUO off = Mode TC
If mode DUO is not selected, the receiver switches au-
tomatically into mode TC.
OFF * Mode DUO off = Standby
If mode DUO is not selected, the receiver switches to
standby automatically.
10 Activation
ON ** Transmitter power for activation signal (flash) 50%
OFF * Transmitter power for activation signal (flash) 100%
S W Function Status Description
* status of delivery ** not valid for radio transmission
On
....
Off
On
....