V3A | 08/2018
39
© by Blum-Novotest
Measuring sequence
6.2 TC - level controlled - SW8=ON
Not available for radio transmission
Fig. 6-2
(1) Standby
(2) Mode TC
(3) Activate probe
(M-Code)
(4) Deflect stylus
(5) Stylus initial position
(6) Error transmission interrupted (SW8=ON,
SW4=OFF)
(7) Error rectified
(8) Warning: Battery low (SW5=OFF)
(9) Deactivate probe (M-Code)
(10) Exchange probe / standby
1 2 3 4
ON
5 6 7 8 9 10
1 2 3 4
ON
STATUS2 (N/O)
normally open
START
Mode TC
Mode DUO
H
L
H
L
H
L
H
L
H
L
H
L
H
L
X/Y
!
!!
!
!!
Z
12345678 910
BATTERY
ERROR
STATUS1
STATUS1
closed open closed closed closedopen openopen open