V3A | 08/2018
38
© by Blum-Novotest
Measuring sequence
6. Measuring sequence
6.1 TC - level controlled - SW8 = OFF
Fig. 6-1
(1) Standby
(2) Mode TC
(3) Activate probe
(M-Code)
(4) Deflect stylus
(5) Stylus initial position
(6) Error transmission interrupted (SW8=OFF,
SW4=OFF)
(7) Error rectified
(8) Warning: Battery low (SW5=OFF)
(9) Deactivate probe (M-Code)
(10) Exchange probe / standby
1
2
3
4
ON
5
6
7
8
9
10
1 2 3 4
ON
STATUS2 (N/O)
normally open
START
Mode TC
Mode DUO
H
L
H
L
H
L
H
L
H
L
H
L
H
L
!!
!!
12345678 910
BATTERY
ERROR
STATUS1
STATUS1
closed open closed closed closedopen openopen open