contact support@blustream.com.au | support@blustream.co.uk
MFP62 USER MANUAL
09
RS-232 Control Port
Baud Rate: 57600 bps
Data Bit: 8-bit
Parity: None
Stop Bit: 1-bit
Flow Control: None
The MFP62 can be controlled via a 3-pin Phoenix to serial RS-232 cable (supplied). All RS-232 commands must be terminated with
a carriage return <CR> or \r. The communication settings and commands are as follows:
RS-232 COMMAND DESCRIPTION
? Print Help Information
HELP
Print Help Information
STATUS Print System Status And Port Status
P ON/OFF Set System Power On or O
KEY ON/OFF Set System Key Control On Or O
IR ON/OFF Set System IR Control On Or O
LCD ON/OFF Set LCD Always On Or Auto Turn O In Power On State
RESET Reset System To Default Setting
(Type “Yes” To Confirm, “No” To Discard)
RESET ALL Reset System And Network To Default Setting
(Type “Yes” To Confirm, “No” To Discard)
OUT OSD ON/OFF Set Scaler OSD Show On or O
OUT RES rr Set Scaler Output Resolution
rr=00: 1024x768@60Hz
rr=01: 1280x800@60Hz
rr=02: 1360x768@60Hz
rr=03: 1440x900@60Hz
rr=04: 1680x1050@60Hz
rr=05: 1920x1200@60Hz
rr=06: 720p@50Hz
rr=07: 720p@60Hz
rr=08: 1080p@50Hz
rr=09: 1080p@60Hz
rr =10: 4K2K@25Hz
rr=11: 4K2K@30Hz
rr=12: 4K2K@50Hz
rr=13: 4K2K@60Hz
rr=14: DCI 4K2K@25Hz
rr=15: DCI 4K2K@30Hz
rr=16: DCI 4K2K@50Hz
rr=17: DCI 4K2K@60Hz
rr=18: Auto
OUT FREQ mm Set Output Frequency Mode
mm=AUTO: Set Output Freq To Auto Change To Input Freq
mm=FORCE: Set Output Freq By CMD OUT RES rr Select
OUT xx ON/OFF Set Output xx On Or O
xx=00: Select All OUTPUT Ports
xx=[01...02]: Select One OUTPUT Port
OUT xx FR yy Select Input Port yy
yy=[01...03:HDMI, 04:DP, 05:USB-C, 06:VGA]
NET DHCP ON/OFF Set Auto IP(DHCP) ON Or OFF
NET IP xxx.xxx.xxx.xxx Set IP Address
NET GW xxx.xxx.xxx.xxx Set Gateway Address
NET SM xxx.xxx.xxx.xxx Set Subnet Mask Address
NET RB Set Network Reboot and Apply New Config!!!
NET TN xxxx Set Telnet Port