Maintenance 5.3 Regular maintenance work
Page 44 BOGE Operating instructions for C 10 L...C 20 L series screw compressors
Flushing the oil circuit
Flushing the oil circuit with clean oil becomes necessary:
When the oil is excessively soiled.
Prior to changing the oil type.
Cleaning the compressed
air/oil cooling unit
Cleaning:
After 1,500 operating hours, however, at the latest after one year.
Switch off the compressor using the OFF button.
Fig. 5.8: Cleaning the compressed air/oil cooling unit
Attention!
Detailed information as to the flushing with BOGE oils you can obtain from
the following service number:
Telephone: +1-770-874-1570
Telephone: +49 5206 601-140
Note!
The service life of the compressed air/oil cooling unit depends on the degree
of soiling (dust, oil vapour) of the suctioned cooling air. Extreme external soil
-
ing of the cooling unit leads to an increased temperature in the oil circuit.
Caution: Risk of injury!
Press Emergency Stop button, open mains disconnection device and secure
against unintentional switch on by means of a padlock.
Attention!
Do not use any sharp objects for cleaning!
These could damage the cooling unit.
Blow down the dirt with
compressed air in the
opposite direction to the
normal cooling air flow.
Vacuum out the dirt using
an industrial vacuum
cleaner.
If the cooling unit is exces-
sively soiled (cleaning is no
longer possible with com
-
pressed air), have it disas-
sembled and cleaned by
BOGE service.