Operation
BOMAG
26
BPH 80/65
3.10 Stopping the vibratory
plate, shutting the engine
down
!
Danger
Danger of accident!
Stop the vibratory plate with the travel lever
(toggle switch) first, before switching the vi-
bration off.
Fig. 22
l Actuate the travel lever (toggle switch) until the
vibratory plate vibrates on the spot (Fig. 22) .
Fig. 23
l Press the push button vibration "ON/OFF"
(Fig. 23) .
Vibration is switched off.
!
Caution
Do not shut the engine down all of a sudden
from full load, but let it idle for a while for tem-
perature equalization.
Fig. 24
l Shift the throttle lever to position "Min" (Fig.
24) and let the engine run with idle speed for a
short while.
Fig. 25
l To shut the engine down turn the ignition key
to position "0" (Fig. 25) and pull it out. The
warning buzzer stops.