11/06 11
4.1.3 ACT/ACU 401 (0.55 to 4.0 kW, 400 V)
Type designation
ACT/ACU 401 -05 -07 -09 -11 -12 -13 -15 -18
Motor-side output
Recommended
motor shaft output
P kW 0.55 0.75 1.1 1.5 1.85 2.2 3.0 4.0
Mains-side input
Nominal voltage
U
V 400
Energy dissipation,
heat sink [2 kHz]
P
v
W 40 46 58 68 68 87 115 130
Energy dissipation,
interior
P
v int
W 12 15 18 20 21 25 31 35
Thermal resistance
Thermal resistance
R
th
K/W
1.0 0.87 0.69 0.59 0.59 0.46 0.35 0.31
Mechanical
Dimensions
HxWxD
mm 190x82x140 250x85x140
Heat sink HxW mm 170x82 230x85
T
k max
–T
U
ΔT K 40
4.1.4 ACT/ACU 401 (5.5 to 15.0 kW, 400 V)
Type designation
ACT/ACU 401 -19 -21 -22 -23 -25
Motor-side output
Recommended
motor shaft output
P kW 5.5 7.5 9.2 11.0 15.0
Mains-side input
Nominal voltage
U
V 400
Energy dissipation,
heat sink [2 kHz]
P
v
W 145 200 225 240 310
Energy dissipation,
interior
P
v int
W 48 61 68 81 107
Thermal resistance
Thermal resistance
R
th
K/W
0.24 0.18 0.16 0.15 0.11
Mechanical
Dimensions
HxWxD
mm 250x125x144 250x150x144
Heat sink HxW mm 230x125 230x150
T
k max
–T
U
ΔT K 40