Page 10 3BE390758NU – 12/11
BONNET GRANDE CUISINE
Registered Office:
Rue des Frères Lumière - Z.I Mitry Compans
F-77292 MITRY MORY Cedex
2.2 VISUALISATION OF DEFECTS
Switch for adjustment of set temperature
Each defect is shown on the display indicating the set temperature.
The defects E50 to E99 stop cooking or prevent the start of cooking
and are announced by a “beep”.
Probe defects
- E40: 1 or 2 (out of 3) core probe feelers cut.
- E41: 1 or 2 (out of 3) core probe feelers short-circuited.
- E61: Ambient probe short-circuited.
- E62: Ambient probe cut.
- E63: Missing or cut core probe.
- E64: Short-circuited core probe.
Other defects
- E42: Electronic controls internal temperature exceeded.
- E43: Saturated steam injection activated for more than 30 secs in steam mode.
(Condenser nozzle encrusted, condenser fed with hot water or insufficient flow of water).
- E46: Communication fault between the relay and facia cards.
- E51: Ambient temperature set to 0.
- E52: Time or core temperature set to 0.
- E53: Ventilation not functional.
- E67: Gas safety inlet activated.
- E68: Temperature of oven capacity at + 290°C.