LTC 2600 Series | Instruction Manual | Multiplexer Set (MS) Commands
Bosch Security Systems | July 12, 2004
EN
|
19
Parameter values for <password> are
<digit><digit><digit><digit> where <digit> equals
any number between 0 and 9.
MS-SEQ-DWELL <monitor> <mon-mode> <dwell-
time>
This command sets the sequence dwell time for the
specified monitor in the specified display mode.
Parameter values for <monitor>, <mon-mode>, and
<dwell-time> are:
<monitor> 1 Monitor A
2Monitor B
<mon-mode> 1 Full screen mode
2 Quad mode
<dwell-time> 0 Sequence disabled
1-60 Dwell time in seconds
MS-SEQ-DWELL-TIME <seq-device> <dwell-time>
This command sets the sequence dwell time for the
specified monitor in the specified display mode (<seq-
device>).
Parameter values for <seq-device> and <dwell-time>
are:
<seq-device> 1 Monitor A - Full screen
2Monitor A - Quad
3Monitor B - Full screen
4Monitor B - Quad
<dwell-time> 0 Sequence disabled
1-61 Dwell time in seconds
For new applications, use the MS-SEQ-DWELL
command instead of this one.
MS-SEQ-ENABLE <monitor> <boolean>
This command enables or disables sequencing for the
specified monitor if its display mode is Full or Quad.
Parameter values for <monitor> and <boolean> are:
<monitor> 1 Monitor A
2Monitor B
<boolean> 0 Disable sequencing
1 Enable sequencing
MS-SEQ-LIST <monitor> <display-mode> <camera
list>
This command defines the sequence (i.e. camera-to-
cameo assignment) for the specified display mode on
the specified monitor.
Parameter values for <monitor>, <display-mode>, and
<camera list> are:
<monitor> 1 Monitor A
2Monitor B
<display-mode> 0 Full screen
1 Single quad
2 3x3 multi
3 4+3 multi
412+1 multi
5 4x4 multi
6 8+2 multi
<camera list> A list of camera numbers
(1-32) given in the order
desired for the
sequence/display. (See the
following example).
EXAMPLE: The diagram and sample command
syntax illustrates the functioning of sequence lists for
the quad mode.
1 2
3 4
5 6
7 8
91 0
11 12
29 30
31 32
...
First Step, :00-:05 sec Second Step, :05-:10 Third Step, :10-:15
Eighth Step, :35-:40
LTC 2600> MS-SEQ-LIST 1 1 1 2 3 4 5 6 7 8 9 10 11 12 … 29 30 31 32