LTC 2600 Series | Instruction Manual | Multiplexer Read (MR) Commands
Bosch Security Systems | July 12, 2004
EN
|
28
4.2 Detailed Descriptions of MR
Commands
MR-ACTION-ALARM-RELAY
NOTE: This command returns the settings for Relay 1
only.
Parameter values returned are <responds to> and
<polarity>:
<responds to> 0 Neither (never activates>
4 Relay activates on action
5 Relay activates on alarm
6 Relay activates on action or
alarm
<polarity> 0 Normally open (N/O)
1Normally closed (N/C)
MR-ACTION-BEEPER
This command reports the action beeper setting as
follows:
0 Disabled
1 Enabled
MR-ACTION-CAPTURE
This command returns the action capture time setting.
Parameter values for <time> are any value from <3>
to <60> seconds.
MR-ACTION-ENABLE
This command returns the values of enabled
multiplexer action detectors corresponding to the
values specified in a 16-position (bit) table. The value
in each position of the table corresponds to the state of
a specific action detector (a value of 1 represents an
enabled action detector; a value of 0 is a disabled
action detector).
Parameter values for <table 16> (returned value) range
from <0> to <65535> (decimal) OR <0> to <FFFF>
(hex).
MR-ACTION-HISTORY
This command returns the action status history for
cameras in the <camera map>.
NOTE: The <camera map> consists of a 16-bit map
with a bit for each camera in the multiplexer. The least
significant bit corresponds to camera 1; the most
significant bit corresponds to camera 16. A set bit
corresponds to an enabled or active camera, depending
on the contact.
MR-ACTION-SENSITIVITY <camera#>
This command returns the action detector sensitivity
<level> for the specified camera.
Parameter values for <camera# > and <level > are as
follows:
<camera# > 1 to 16
<level> 1 to 4 (with 4 being the highest
sensitivity)
MR-ACTION-SETUP
This command returns the action manual reset and
camera history settings, respectively.
Parameter values are:
0 Disabled
1Enabled
MR-ACTION-ZONEDRAW
NOTE: This command is only supported for binary
protocol.
This command returns the setting for real-time zone
drawing on monitor A.
Parameter values for <zone draw setting> are:
0 Disabled
camera# Enabled; the specified
camera is selected for
monitor A in full-screen
mode, and real-time drawing
is enabled for that camera-
overriding any other use of
monitor A.

Related product manuals