LTC 2600 Series | Instruction Manual | Multiplexer Set (MS) Commands
Bosch Security Systems | July 12, 2004
EN
|
21
If the settings were never saved or if the DEFAULT
command is used, the Save memory locations will
contain the default system settings.
Parameter values for <action> are as follows:
10 Save settings to Save Memory 1
11 Save settings to Save Memory 2
12 Save settings to Save Memory 3
13 Save settings to Save Memory 4
14 Save settings to Save Memory 5
15 Save settings to Save Memory 6
20 Restore settings from Save Memory 1
21 Restore settings from Save Memory 2
22 Restore settings from Save Memory 3
23 Restore settings from Save Memory 4
24 Restore settings from Save Memory 5
25 Restore settings from Save Memory 6`
EXAMPLE: To save the current system configuration
(results of CCL commands and front panel keypad
menu entries), a value of 10 is used for <action> (saves
the settings into memory #1).
MS-TIME-EVENT <item> <begin-date> <begin-
time> <end-date> <end-time> <function> <log>
<interval> <SMTWTFS> <status>
This command sets up the necessary parameters for a
time-event.
Time-events are used to program the multiplexer to
perform specified functions automatically at certain
times of the day/month/year. Up to 64 different time-
events may be programmed. The time-event functions
use either a Saved Memory (see MS-SYSTEM-
SETTINGS command) OR a CCL command string
(see the MS-TIME-EVENT-COMMAND command).
NOTE: For additional information on the time-event
parameters, please refer to Appendix B at the back of
the manual.
Parameter values are defined as follows:
<item> 1 to 64 (time-event reference #)
NOTE: Event numbers from 59 to 64 are
reserved for the menu time-events. For these
events:
Only the <begin-time>, <function>,
<interval>,<SMTWTFS>, and the <status>
information can be modified>
The <interval> parameter can be set only as
once (0) or daily (3).
The <function> parameter can be set to only
two values: 30 = record OFF, 31 = record
ON.
<begin-date> MM DD YY (spaces between)
<begin-time> HH MM (24 hr format, 5 minute
intervals)
<end-date> MM DD YY (spaces between) ;
00 00 00 (event has no end date)
<end-time> HH MM (24 hr format, 5 minute
intervals) ;
00 00 (event has no end time)
<function> 20 to 25 (Restore settings from Save
Memories 1 - 6) ;
101 to 116 (Execute the CCL
command(s) specified by MS-TIME-
EVENT-COMMANDS 101
through 116)
<log> 0 = No monitor message on time-
event
1 = Display monitor message on
time-event
<interval> 0 = Occurs only once
1 = Occurs every five minutes
2 = Occurs once an hour
3 = Occurs once a day
4 = Occurs once a month
5 = Occurs once a year