Loading...
LTC 2600 Series | Instruction Manual | Multiplexer Set (MS) Commands
Bosch Security Systems | July 12, 2004
EN
|
26
MS-WINTER-TIME <date>
This command sets the date when the time-of-day
clock will be put back by one hour (from Daylight
Saving Time back to Standard Time). At 2:00 a.m. /
02:00 on the date set, the hour is put back to 1:00 a.m.
/ 01:00.
MS-ZOOM <monitor> <cameo#> <boolean>
This command enables or disables the zoom function
for the specified cameo on the specified monitor.
NOTE: If the specified monitor is in full screen mode,
the cameo specification is redundant (i.e. unnecessary).
If the boolean parameter is 0, zoom is turned off, and
the cameo specification is also redundant.
Parameter values for <monitor>, <cameo#> and
<boolean> are:
<monitor> 1 Monitor A
8 Monitor B
<cameo#> 1 to 16
<boolean> 0 Disable
1 Enable
MS-ZOOM-SCROLL <monitor> <direction>
This command scrolls the specified monitor display in
the specified direction when in zoom mode.
Parameter values for <monitor> and <direction> are:
<monitor> 1 Monitor A
2Monitor B
<direction> 1 Up
2 Right
3Down
4 Left