LTC 2600 Series | Instruction Manual | Multiplexer Read (MR) Commands
Bosch Security Systems | July 12, 2004
EN
|
36
MR-VCR-ACTION-RECORD <vcr>
This command returns the action record mode for the
specified VCR.
Parameter values are:
<vcr> 1 VCR output
2VCR/Monitor B output
<record mode> 0 OFF
(returned value) 1 Exclusive (records only the
action cameras)
2 Interleave (records the action
cameras in addition to the
cameras specified by the MS-
VCR-RECORD-LIST)
MR-VCR-ALARM-RECORD <vcr>
This command returns the alarm record mode for the
specified VCR.
Parameter values are:
<vcr> 1 VCR output
2VCR/Monitor B output
<record mode> 0 OFF
(returned value) 1 Exclusive (records only the
alarm cameras)
2 Interleave (records the alarm
cameras in addition to the
cameras specified by the MS-
VCR-RECORD-LIST)
MR-VCR-CUSTOM <custom-vcr-model#> <vcr-
mode>
This command returns the parameters for the custom
VCR definition specified by <custom-vcr-model#>
and <vcr-mode>.
Parameter values are as follows:
<custom-vcr-model#> 1 to 6 (corresponding to
custom VCR setting 1 to 6)
<vcr-mode> 1 to 20
<hour-rate> (returned)
<field-rate-MSB> (returned)
<field-rate-LSB> (returned)
<play-times> (returned)
0SP
1LP
MR-VCR-MODEL <vcr>
This command returns the VCR model number
corresponding to the VCR attached to the output as
defined by <vcr>.
Parameter values are as follows:
<vcr> 1 VCR output
2VCR/Monitor B output
<vcr-model#> Defined as <standard-vcr-
model#>
(manufacturer/model#) OR
<custom-vcr-model#>
(corresponding to custom
VCR setting 1 to 6)
MR-VCR-PLAYBACK-ALGORITHM
This command returns the teletext playback algorithm.
MR-VCR-RECORD-ALGORITHM
This command returns the teletext record algorithm.